Industrial Automation Parts. Prompt replies from real people.

ABB OT1000BLRR3TZ Reliable and Safe Switch-Disconnectors

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the ABB OT1000BLRR3TZ?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB OT1000BLRR3TZ cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
OT1000BLRR3TZ
Material Number
1SCA022340R3520
Manufacturer
ABB
Product ID
86659

Get a Free Quote

Request pricing and availability for OT1000BLRR3TZ.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
acc. to IEC 60529 IP65
Product Net Weight
62.67 kg
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A
Rated Operational Power AC-23A (Pe)
(380 ... 415 V) 560 kW (500 V) 710 kW (690 V) 1000 kW
Rated Operational Voltage
Main Circuit 1000 V
See all specifications

Product Highlights

  1. Current Rating: Conventional thermal current 1000 A in fully enclosed configuration, with AC-22A and AC-23A operational current of 1000 A at 380 to 415 V, 500 V, and 690 V
  2. Switching Capacity: Rated operational power AC-23A of 560 kW at 380 to 415 V, 710 kW at 500 V, and 1000 kW at 690 V, with rated short-circuit making capacity of 110 kA at 690 V AC and short-time withstand current of 50 kA for 1 s
  3. Enclosure and Protection: IP65 degree of protection acc. to IEC 60529, IK09 impact resistance, steel sheet enclosure, pollution degree 3, and 3-pole configuration with no neutral terminal
  4. Terminals and Wiring: Line and PE terminals top in bottom out, cable entry top or bottom with 8 ring-flange outlets per side and knock-outs of 3x10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm, main circuit screw clamp with 12 mm hole diameter and 75 N·m tightening torque, PE terminal capacity 10 pc 25 to 120 mm²
  5. Auxiliary Contacts: 2 NO and 1 NC mounted auxiliary contacts, maximum 2 NO and 2 NC
  6. Dimensions and Standards: 800 mm width, 1200 mm height, 330 mm depth, 62.67 kg net weight, rated insulation voltage 1000 V acc. to IEC/EN 60664-1, and compliance with IEC 60947-1 and IEC 60947-3
OT1000BLRR3TZ

Product Information

Technical Specifications

Specifications for OT1000BLRR3TZ

ParameterValue
Degree of Protectionacc. to IEC 60529 IP65
Pollution Degree3
Product Net Width800 mm
Product Net Height1200 mm
Product Net Depth / Length330 mm
Product Net Weight62.67 kg
Cable Entry PositionTop/Bottom
Cable Outlets Per Side8xring-flange / 8xring-flange, Knock-outs: 3x10mm, 12.5mm, 20.5mm, 25.5mm, 32.5mm
Connecting Capacity Main CircuitHole Diameter 12 mm Screw Clamp / PE Terminal 10pc,25 ... 120 mm²
Conventional Thermal Current (Ithe)Fully Enclosed 1000 A
Degree of Protectionacc. to IEC 60529 IP65
Enclosure MaterialSteel sheet
Handle ColorBlack
Handle TypePistol handle
Impact Resistance RatingHousing IK09
Maximum Mounted Auxiliary Contacts2 NO, 2 NC
Mounted Auxiliary Contacts2 NO, 1 NC
Neutral TypeNo neutral terminal
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO2
Number of Poles3P
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out
Position of PE TerminalsTop In - Bottom Out
ParameterValue
Power Lossat Rated Operating Conditions per Pole 19 W
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A
Rated Operational Power AC-23A (Pe)(380 ... 415 V) 560 kW (500 V) 710 kW (690 V) 1000 kW
Rated Operational VoltageMain Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)(690 V AC) 110 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 50 kA
Recommended Screw DriverMain Circuit M12
StandardsIEC 60947-1, -3
Tightening TorqueMain Circuit 75 N·m
Recommended Screw DriverMain Circuit M12
Tightening TorqueMain Circuit 75 N·m
Object Classification CodeQ
ETIM 8EC000216 - Switch disconnector
ETIM 9EC000216 - Switch disconnector (low voltage)
UNSPSC39122205
IDEA Granular Category Code (IGCC)5166 >> Safety switch
eClassV11.1 : 27371403
WEEE Category4. Large Equipment (Any External Dimension More Than 50 cm)
E-Number (Finland)3642713
E-Number (Norway)1429138
E-Number (Sweden)3140638
Manufacturer ID1SCA022340R3520

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp