Product Model
OT40FT4N2
Material Number
1SCA104956R1001
Manufacturer
ABB
Product ID
86628

Get a Free Quote

Request pricing and availability for OT40FT4N2.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
Front IP20
Product Net Weight
0.13 kg
Rated Conditional Short-Circuit Current (Inc)
(40 A fuse, ≤415V) 50 kA (25 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 750 V
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 5.5 kW (400 ... 415 V) 11 kW (500 V) 11 kW (690 V) 11 kW
See all specifications

Product Highlights

  1. Electrical Ratings: 40 A rated operational current at 380 to 690 V AC in AC-21A and AC-22A, 23 A at 380 to 500 V AC and 12 A at 690 V AC in AC-23A, with 750 V rated insulation voltage and 8 kV rated impulse withstand voltage
  2. Power Switching Capacity: Rated operational power of 5.5 kW at 220 to 240 V AC and 11 kW at 400 to 690 V AC in AC-23A, with UL/CSA horsepower ratings up to 25 Hp at 550 to 600 V AC three phase
  3. Short-Circuit Withstand: 50 kA rated conditional short-circuit current with a 40 A fuse at up to 415 V or a 25 A fuse at 690 V, and 0.5 kA rated short-time withstand current for 1 s
  4. Four-Pole Configuration: 4P front-operated switch with the fourth pole switched simultaneously on the right side, line terminals usable top-in bottom-out or bottom-in top-out, and mechanism mounted on top of the switch
  5. Connection and Mounting: Screw terminals for Cu conductors from 0.75 to 10 mm², 9 to 10 mm wire stripping length, 0.8 N·m tightening torque, Pozidriv 2 screwdriver, and door mounting with front IP20 protection
  6. Dimensions and Durability: 54 mm height, 48.5 mm width, 52 mm depth, 0.13 kg net weight, and 20000 mechanical operations
  7. Standards and Compliance: IEC 60947-3, UL 508, and CSA C22.2 No. 14, with maximum operating voltage 600 V UL/CSA and pollution degree 3
OT40FT4N2

Product Information

Technical Specifications

Specifications for OT40FT4N2

ParameterValue
Degree of ProtectionFront IP20
Environmental Information1SCC301262D0201
Pollution Degree3
Product Net Width48.5 mm
Product Net Height54 mm
Product Net Depth / Length52 mm
Product Net Weight0.13 kg
Cable Cross-SectionCu 0.75 ... 10 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1x Cu 0.75…4 mm² Solid 1x Cu 0.75…6 mm² Flexible 1x Cu 0.75…10 mm² Stranded 1x Cu 0.75…10 mm²
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 40 A
Conventional Thermal Current (Ithe)Fully Enclosed 40 A
Degree of ProtectionFront IP20
Distance Between PhasesStandard
Fourth Pole PositionRight Side
Fourth Pole TypeSwitched - Simultaneous Function
Handle TypeHandle and shaft not included
Lock TypeNo
Mechanical Durability20000
Mounting TypeDoor mounting
Number of Poles4P
Operating ModeFront operated
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out Bottom In - Top Out
Power Lossat Rated Operating Conditions per Pole 1.6 W
Rated Conditional Short-Circuit Current (Inc)(40 A fuse, ≤415V) 50 kA (25 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)(380 ... 415 V) 40 A (500 V) 40 A (690 V) 40 A
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 40 A (500 V) 40 A (690 V) 40 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 23 A (500 V) 23 A (690 V) 12 A
ParameterValue
Rated Operational Power AC-23A (Pe)(220 ... 240 V) 5.5 kW (400 ... 415 V) 11 kW (500 V) 11 kW (690 V) 11 kW
Rated Operational VoltageMain Circuit 750 V
Rated Short-Circuit Making Capacity (Icm)(690 V) 0.71 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 0.5 kA
Recommended Screw DriverMain Circuit Pozidriv 2
Special FunctionsNo
StandardsIEC 60947-3UL 508CSA C22.2 No. 14
Switches Operating MechanismMechanism on Top of the Switch
Terminal TypeScrew Terminals
Tightening Torqueacc. IEC 60947-1 0.8 N·m
Wire Stripping LengthMain Circuit 9-10 mm
Maximum Operating Voltage UL/CSA600 V
Ampere Rating40 A
Horsepower Rating UL/CSA(110 ... 120 V AC) Single Phase 2 Hp (240 V AC) Single Phase 5 Hp (440 ... 480 V AC) Single Phase 10 Hp (550 ... 600 V AC) Single Phase 15 Hp (220 ... 240 V AC) Three Phase 10 Hp (440 ... 480 V AC) Three Phase 20 Hp (550 ... 600 V AC) Three Phase 25 Hp
Wire Stripping LengthMain Circuit 9-10 mm
Recommended Screw DriverMain Circuit Pozidriv 2
Tightening Torqueacc. IEC 60947-1 0.8 N·m
Tightening Torque UL/CSA7 in·lb
Object Classification CodeQ
ETIM 8EC000216 - Switch disconnector
ETIM 9EC000216 - Switch disconnector (low voltage)
UNSPSC39122233
IDEA Granular Category Code (IGCC)5290 >> Disconnect switch
eClassV11.1 : 27371403
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)3601447
E-Number (Norway)4363539
E-Number (Sweden)3171084
Manufacturer ID1SCA104956R1001