- AF26-30-00-14LU
ABB AF26-30-00-14LU is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current is 26 A at 220/230/240 V, 380/400 V, 415 V, and 440 V AC-3 at 60 °C, 23 A at 500 V, and 17 A at 690 V. Rated operational power AC-3 is 6.5 kW at 220/230/240 V, 11 kW at 380/400 V and 415 V, and 15 kW at 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF26-30-00K-11
The ABB AF26-30-00K-11 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.325 kg. Rated operational voltage for the main circuit is 690 V, with a rated frequency of 50/60 Hz for both control and main circuits. Rated operational current AC-3 is 26 A at 380/400 V and 60 °C, and rated operational power AC-3 is 11 kW at 380/400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. The manufacturer ID is 1SBL237005R1100.
- AF26-30-00K-12
The ABB AF26-30-00K-12 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 50 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 26 A at 415 V and 60 °C, and rated operational power is 11 kW at 415 V. Maximum electrical switching frequency in AC-3 is 1200 cycles per hour. Dimensions are 45 mm wide, 86 mm deep, and 92.3 mm high, with a net weight of 0.325 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF26-30-00K-13
The ABB AF26-30-00K-13 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.325 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 50 A at 40 °C. AC-3 ratings include 26 A at 380/400 V and 11 kW at 380/400 V, both at 60 °C. Maximum electrical switching frequency is 1200 cycles per hour in AC-3. The contactor is declared to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL237005R1300.
- AF26-30-00K-13M
The ABB AF26-30-00K-13M is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, weighing 0.325 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current Ith is 50 A at 40 °C. Rated operational current AC-3 is 26 A at 415 V and 60 °C, and rated operational power AC-3 is 11 kW at 415 V. Standards include IEC 60947-1 / 60947-4-1, EN 60947-1 / 60947-4-16, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF26-30-00K-14
The ABB AF26-30-00K-14 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.365 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 26 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 380/400 V and 415 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF26-30-00L-13
The ABB AF26-30-00L-13 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 50 A at 40 °C. Rated operational current AC-1 is 45 A at 40 °C, 40 A at 60 °C, and 32 A at 70 °C, all at 690 V. Control circuit voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF26-30-00L-14
The ABB AF26-30-00L-14 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. The control circuit operates at 50/60 Hz, 250 to 500 V, and at 250 to 500 V DC. Conventional free-air thermal current is 50 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.