- OT160EVUUR3AZ-L21
ABB isolating switch OT160EVUUR3AZ-L21, manufacturer ID 1SCA156602R1001. Enclosed non-fusible switch with conventional thermal current (Ithe) 160 A fully enclosed. Enclosure type MSC in steel sheet, 400 mm wide, 600 mm high, 230 mm deep, 23.91 kg. Degree of protection acc. to IEC 60529 IP65; housing impact resistance IK09; pollution degree 3. Cable entry down/down, with blank and 4x ring-flange outlets and knock-outs of 3x10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. Main circuit connection: screw clamp, hole diameter 8 mm, PE terminal 2 pc, 10 to 70 mm². Red/yellow pistol handle. Mounted auxiliary contacts 2 NO, 1 NC; maximum 2 NO, 2 NC. Mechanical durability 20000. No neutral terminal.
- OT160EVUUR3TZ
The ABB OT160EVUUR3TZ is a 3-pole isolating switch with a fully enclosed conventional thermal current (Ithe) rating of 160 A. It is supplied in an MSC-type steel sheet enclosure measuring 400 mm wide, 600 mm high, and 230 mm deep, with a net weight of 21.91 kg. The enclosure provides IP65 protection according to IEC 60529 and an impact resistance rating of IK09. Cable entry is bottom/bottom, with blank or 4x ring-flange outlets per side and knock-outs of 3x10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. Main circuit connection uses an 8 mm hole diameter screw clamp, with a PE terminal for 2 pc, 10 to 70 mm². The black pistol handle operates an interlocked cover with defeatable interlocking. Mounted auxiliary contacts are 2 NO and 1 NC, with provision for up to 2 NO and 2 NC. No neutral terminal is included.
- OT160EVUUR3TZ-L21
ABB isolating switch OT160EVUUR3TZ-L21, manufacturer ID 1SCA153801R1001, in an MSC steel sheet enclosure measuring 400 mm wide, 600 mm high and 230 mm deep, 23.91 kg. It is a 3-pole, non-fusible switch with no neutral terminal, a black pistol handle and bolt terminals. Conventional thermal current is 160 A fully enclosed. Rated insulation voltage is 1000 V acc. to IEC/EN 60664-1; rated operational voltage main circuit 1000 V. Rated operational current AC-22A and AC-23A is 160 A at 380 to 415 V, 500 V and 690 V. Rated operational power AC-23A is 80 kW at 380 to 415 V, 112 kW at 500 V and 144 kW at 690 V. Degree of protection IP65 acc. to IEC 60529; housing impact resistance IK09; pollution degree 3. Standards IEC 60947-1, -3.
- OT160EVUUR3TZ-L22
ABB isolating switch OT160EVUUR3TZ-L22, manufacturer ID 1SCA153802R1001. Three-pole (3P) switch-disconnector in an MSC steel sheet enclosure, IP65 acc. to IEC 60529, IK09 housing impact resistance, pollution degree 3. Conventional thermal current 160 A fully enclosed; rated operational current 160 A at 380 to 415 V, 500 V, and 690 V for AC-22A and AC-23A. Rated operational power AC-23A is 80 kW at 380 to 415 V, 112 kW at 500 V, and 144 kW at 690 V. Rated insulation voltage 1000 V acc. to IEC/EN 60664-1; rated operational voltage 1000 V. Rated conditional short-circuit current 40.5 kA; rated short-circuit making capacity 30 kA at 690 V. Standards IEC 60947-1 and IEC 60947-3. Dimensions 400 mm wide, 600 mm high, 230 mm deep; net weight 23.91 kg.
- OT160G03
The ABB OT160G03 is a 3-pole front-operated switch-disconnector, order code 1SCA135134R1001. It has a rated operational current of 160 A at 380-415 V, 500 V, and 690 V, a rated insulation voltage of 1000 V, and a conventional free-air thermal current (Ith) of 160 A at 40 °C. The enclosed thermal current (Ithe) is 160 A. Dimensions are 123 mm wide, 130 mm high, and 73 mm deep, with a net weight of 0.8 kg. It accepts Cu cable cross-sections from 10 to 70 mm², offers front IP20 protection, pollution degree 3, base mounting, and 20000 mechanical operations. The handle and shaft are not included.
- OT160G03/B10
ABB OT160G03/B10 isolating switch, 3-pole, with screw terminals. Rated insulation voltage 1000 V according to IEC/EN 60664-1; rated operational voltage of the main circuit 1000 V. Conventional thermal current Ithe 160 A fully enclosed. Rated operational current AC-22A and AC-23A: 160 A at 380 to 415 V, 500 V, and 690 V. Rated operational power AC-23A: 45 kW at 220 to 240 V, 75 kW at 400 to 415 V, 90 kW at 500 V, 132 kW at 690 V. Rated impulse withstand voltage 12 kV; rated short-circuit making capacity 12 kA at 690 V; rated short-time withstand current 4 kA for 1 s. Cable cross-section Cu 10 to 70 mm². Front degree of protection IP20; pollution degree 3. Mechanical durability 20000 operations. Power loss 6.5 W per pole at rated operating conditions. Standards: IEC 60947-3, UL 98, CSA C22.2 NO.4. Handle and shaft not included.
- OT160G03K
The ABB OT160G03K is a 3-pole isolating switch supplied under manufacturer ID 1SCA138208R1001. It is front and side operated with a direct mounted pistol-type handle in black, and includes a lock. The switch has a rated conventional free-air thermal current (Ith) of 160 A at 40 °C and a conventional thermal current (Ithe) of 160 A fully enclosed. Cable cross-section accepts Cu 10 to 70 mm². Dimensions are 123 mm wide, 130 mm high, and 73 mm deep, with a net weight of 0.8 kg. The front degree of protection is IP20, and the pollution degree is 3. Mechanical durability is 20000 operations. Mounting is base mounting.
- OT160G03KL
The ABB OT160G03KL is a 3-pole, front-operated isolating switch for base mounting. It has protected clamp terminals and accepts Cu cable cross-sections from 10 to 70 mm². The conventional thermal current (Ithe) is 160 A fully enclosed. Rated impulse withstand voltage (Uimp) is 12 kV, and rated conditional short-circuit current (Inc) is 100 kA with a 200 A fuse at 500 V and 50 kA with a 200 A fuse at 690 V. Power loss is 6.5 W per pole at rated operating conditions. Mechanical durability is 20000 operations. Front degree of protection is IP20, pollution degree 3. Dimensions are 123 mm wide, 130 mm high, and 73 mm deep; net weight 0.8 kg. Handle and shaft are not included. Manufacturer ID: 1SCA150028R1001.