- AF09ZB-30-10-22
ABB AF09ZB-30-10-22 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 9 A at 380/400 V and 415 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 380/400 V, 415 V, and 440 V, and 5.5 kW at 500 V and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF09ZB-30-10-23
ABB AF09ZB-30-10-23 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, at 60 °C. Rated operational power AC-3 is 4 kW at 415 V, 440 V, and 380/400 V, and 5.5 kW at 500 V and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF09ZB-30-10K-21
The ABB AF09ZB-30-10K-21 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.315 kg. The main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, AC-3 ratings include 9 A at 415 V and 60 °C, 9.5 A at 500 V, and 7 A at 690 V; corresponding AC-3 power ratings are 4 kW at 415 V and 5.5 kW at 500 V and 690 V. Standards listed include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, and EN 50155 (applicable parts).
- AF09ZB-30-10K-22
The ABB AF09ZB-30-10K-22 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.315 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, at 60 °C. Rated operational power AC-3 is 4 kW at 415 V and 440 V, and 5.5 kW at 500 V and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF09ZB-30-10K-23
The ABB AF09ZB-30-10K-23 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.315 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational power AC-3 is 4 kW at 380/400 V, 415 V, and 440 V; 5.5 kW at 500 V and 690 V; and 2.2 kW at 220/230/240 V. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, and EN 50155.
- AF09ZB-30-10RT-21
The ABB AF09ZB-30-10RT-21 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, at 60 °C. Rated operational power AC-3 is 4 kW at 415 V and 440 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 or with two M4 screws. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 61373, and EN 50155 (applicable parts).
- AF09ZB-30-10RT-22
The ABB AF09ZB-30-10RT-22 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.32 kg. The rated control circuit voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC operation. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V according to IEC 60947-4-1. Rated operational current AC-3 is 9 A at 415 V and 60 °C, and rated operational power AC-3 is 4 kW at 415 V. Terminals are ring-tongue type. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF09ZB-30-10RT-23
The ABB AF09ZB-30-10RT-23 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.32 kg. The control circuit accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Rated operational current AC-3 is 9 A at 415 V and 440 V, and rated operational power AC-3 is 4 kW at 415 V and 440 V. Rated insulation voltage is 690 V, rated impulse withstand voltage is 6 kV, and rated frequency is 50 or 60 Hz. Terminal type is ring-tongue. DIN-rail mounting per IEC 60715 or diagonal M4 screw mounting is supported. Standards listed include IEC/EN 60947-4-1 and EN 50155 (applicable parts).