Product Model
OTM125F4M230V
Material Number
1SCA122973R1001
Manufacturer
ABB
Product ID
86280

Get a Free Quote

Request pricing and availability for OTM125F4M230V.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
Front IP20
Product Net Weight
1 kg
Motor Operational Voltage
110 ... 240 V AC/DC
Rated Conditional Short-Circuit Current (Inc)
(125 A fuse, 415 V) 50 kA (125 A fuse, 690 V) 18 kA (63 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 22 kW (400 ... 415 V) 45 kW (500 V) 45 kW (690 V) 45 kW
See all specifications

Product Highlights

  1. Electrical Ratings: 4-pole switch-disconnector rated 125 A at 380 to 690 V AC in AC-21A and AC-22A, with AC-23A ratings of 90 A at 380 to 415 V, 70 A at 500 V, and 50 A at 690 V
  2. Switching Capacity: Rated operational power up to 45 kW at 400 to 690 V AC-23A, rated insulation voltage 750 V, rated impulse withstand voltage 8 kV, and rated short-circuit making capacity 3.6 kA at 690 V
  3. Short-Circuit Withstand: Rated conditional short-circuit current of 50 kA at 415 V with a 125 A fuse and 18 kA at 690 V with a 125 A fuse, plus 2.5 kA short-time withstand current for 1 s
  4. Motor and Manual Operation: Motor operating voltage 110 to 240 V AC/DC, direct-mounted black handle for manual operation, and mechanical durability of 20000 operating cycles
  5. Construction and Installation: Base mounting with front operation, line terminals top in and bottom out, screw terminals with 6 N·m tightening torque, and cable cross-section Cu 10 to 70 mm²
  6. Protection and Environment: Front IP20 degree of protection and pollution degree 3, with dimensions 186.5 mm wide, 100 mm high, and 116 mm deep, weighing 1 kg
  7. Standards and Compliance: Designed to IEC 60947-3, with a switched fourth pole on the right side operating simultaneously
OTM125F4M230V

Product Information

Technical Specifications

Specifications for OTM125F4M230V

ParameterValue
Degree of ProtectionFront IP20
Pollution Degree3
Product Net Width186.5 mm
Product Net Height100 mm
Product Net Depth / Length116 mm
Product Net Weight1 kg
Cable Cross-SectionCu 10 ... 70 mm²
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 125 A
Conventional Thermal Current (Ithe)Fully Enclosed 125 A
Degree of ProtectionFront IP20
Distance Between PhasesStandard
Fourth Pole PositionRight Side
Fourth Pole TypeSwitched - Simultaneous Function
Handle ColorBlack
Handle TypeDirect mounted handle
Lock TypeYes
Mechanical Durability20000
Motor Operational Voltage110 ... 240 V AC/DC
Mounting TypeBase mounting
Number of Poles4P
Operating ModeFront operated
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out
Power Lossat Rated Operating Conditions per Pole 6.3 W
Rated Conditional Short-Circuit Current (Inc)(125 A fuse, 415 V) 50 kA (125 A fuse, 690 V) 18 kA (63 A fuse, 690 V) 50 kA
ParameterValue
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 90 A (500 V) 70 A (690 V) 50 A
Rated Operational Power AC-23A (Pe)(220 ... 240 V) 22 kW (400 ... 415 V) 45 kW (500 V) 45 kW (690 V) 45 kW
Rated Operational VoltageMain Circuit 750 V
Rated Short-Circuit Making Capacity (Icm)(690 V) 3.6 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 2.5 kA
Special FunctionsNo
StandardsIEC 60947-3
Switches Operating MechanismMechanism at the End of the Switch
Terminal TypeScrew Terminals
Tightening Torqueacc. IEC 60947-1 6 N·m
Tightening Torqueacc. IEC 60947-1 6 N·m
Object Classification CodeQ
ETIM 8EC000216 - Switch disconnector
ETIM 9EC000216 - Switch disconnector (low voltage)
eClassV11.1 : 27371403
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID1SCA122973R1001