- AFC30-30-00K-81
ABB AFC30-30-00K-81 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.359 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 rated operational current at 60 °C is 32 A at 415 V, 440 V, and 380/400 V; 33 A at 220/230/240 V; 28 A at 500 V; and 21 A at 690 V. AC-3 rated power is 15 kW at 415 V and 380/400 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC30-30-00K-84
ABB AFC30-30-00K-84 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.356 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 32 A at 415 V and 60 °C, and 21 A at 690 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL271005R8400.
- AFC30-30-00K-85
The ABB AFC30-30-00K-85 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 32 A at 415 V and 440 V, 28 A at 500 V, 21 A at 690 V, and 33 A at 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 15 kW at 415 V and 380/400 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC30-30-00K-86
The ABB AFC30-30-00K-86 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 at 60 °C is 32 A at 415 V and 21 A at 690 V. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC30-30-00K-88
The ABB AFC30-30-00K-88 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.351 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. Rated operational current AC-3 is 32 A at 415 V and 440 V, 28 A at 500 V, and 21 A at 690 V, at 60 °C. Rated operational power AC-3 is 15 kW at 415 V and 380/400 V, and 18.5 kW at 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC38-22-00-34
ABB AFC38-22-00-34 is a 4-pole AC contactor with 2 N.O. and 2 N.C. main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.393 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 55 A at 690 V and 40 °C, 45 A at 60 °C, and 37 A at 70 °C. AC-3 ratings include 22 A at 380/400 V and 10.5 A at 690 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC38-22-00-42
The ABB AFC38-22-00-42 is a 3-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.393 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current at 60 °C includes 22 A at 380/400 V and 10.5 A at 690 V; corresponding AC-3 power is 11 kW at 415 V and 9 kW at 690 V. The control circuit is rated 230 to 240 V at 50 Hz and 277 V at 60 Hz. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC38-22-00-80
ABB AFC38-22-00-80 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.393 kg. The main circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 55 A at 690 V and 40 °C, 45 A at 60 °C, and 37 A at 70 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.