- NFZ22E-22 48-130V50/60HZ-DC
ABB NFZ22E-22 48-130V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 4-pole, Contacts configuration: NC x2 + NO x2, and Control voltage1: 48...130V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NFZ22E-23
The ABB NFZ22E-23 is an intermediate relay with manufacturer ID 1SBH136001R2322. It has two normally open and two normally closed auxiliary contacts. The auxiliary circuit is rated 690 V at 50/60 Hz, with a conventional free-air thermal current of 16 A at 40 °C per IEC 60947-5-1. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. The control circuit accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; weight is 0.31 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NFZ22E-23 100-250V50/60HZ-DC
ABB NFZ22E-23 100-250V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 4-pole, Contacts configuration: NC x2 + NO x2, and Control voltage1: 100...250V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NFZ22E-30
ABB NFZ22E-30 intermediate relay, manufacturer ID 1SBH136001R3022. Rated control circuit voltage is 24 V DC. The auxiliary circuit is rated 690 V at 50/60 Hz, with rated insulation voltage 690 V to IEC 60947-5-1 and 600 V to UL/CSA, and rated impulse withstand voltage 6 kV. It has 2 NO and 2 NC auxiliary contacts. Conventional free-air thermal current is 16 A at 40 °C to IEC 60947-5-1. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Dimensions are 45 mm wide, 97 mm deep, 86 mm high; net weight 0.43 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NFZ22EK-20
ABB NFZ22EK-20 intermediate relay, manufacturer ID 1SBH136005R2022. It has 2 NO and 2 NC auxiliary contacts. Rated operational voltage is 690 V for auxiliary and main circuits, with a rated frequency of 50/60 Hz for the auxiliary circuit. Rated control circuit voltage for DC operation is 12 to 20 V. Conventional free-air thermal current is 16 A at 40 °C per IEC 60947-5-1. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight 0.315 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NFZ22EK-21
ABB NFZ22EK-21 intermediate relay, manufacturer ID 1SBH136005R2122. It has 2 NO and 2 NC auxiliary contacts, rated operational voltage 690 V for auxiliary and main circuits, and rated frequency 50/60 Hz for auxiliary and control circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 24 to 60 V at 50 Hz, 24 to 60 V at 60 Hz, and 20 to 60 V DC. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight 0.315 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13. DIN-rail mounting per IEC 60715.
- NFZ22EK-22
The ABB NFZ22EK-22 intermediate relay has 2 NO and 2 NC auxiliary contacts. Its control circuit voltage is 48 to 130 V at 50 Hz, 48 to 130 V at 60 Hz, and 48 to 130 V DC. Rated operational voltage is 690 V for auxiliary and main circuits, with rated insulation voltage 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Conventional free-air thermal current is 16 A per IEC 60947-5-1 at 40 °C. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight is 0.315 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NFZ22EK-23
ABB NFZ22EK-23 intermediate relay, manufacturer ID 1SBH136005R2322. It has 2 NO and 2 NC auxiliary contacts, a 45 mm width, 77 mm depth, 92.3 mm height, and 0.315 kg net weight. The rated control circuit voltage is 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. Rated operational voltage is 690 V for auxiliary and main circuits, with 50/60 Hz rated frequency. Conventional free-air thermal current is 16 A at 40 °C per IEC 60947-5-1. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13. DIN-rail mounting per IEC 60715.