- AFC80-40-00-81
ABB AFC80-40-00-81 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and an insulation voltage of 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), or 600 V per UL/CSA. Conventional free-air thermal current is 125 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Dimensions are 90 mm wide, 119.5 mm deep, and 116 mm high, with a net weight of 1.45 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC80-40-00-84
The ABB AFC80-40-00-84 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.45 kg. The main circuit is rated 1000 V, with conventional free-air thermal current of 125 A according to IEC 60947-4-1 at 40 °C. AC-1 rated operational current is 125 A at 690 V and 40 °C, 105 A at 60 °C, and 90 A at 70 °C. AC-3 rated operational current is 80 A at 415 V and 60 °C, and rated operational power is 45 kW at 415 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC80-40-00-85
The ABB AFC80-40-00-85 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated 1000 V in the main circuit and carries a conventional free-air thermal current of 125 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 80 A at 415 V, 440 V, and 380/400 V at 60 °C, with rated operational power of 45 kW at 415 V and 440 V. Dimensions are 90 mm wide, 119.5 mm deep, and 116 mm high, weighing 1.45 kg. Standards listed are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC80-40-00-86
ABB AFC80-40-00-86 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.45 kg. The main circuit is rated 1000 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 125 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 60 °C. Standards listed are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC80-40-00-88
ABB AFC80-40-00-88 is a four-pole AC contactor, manufacturer ID 1SBL391201R8800, with four normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 119.5 mm deep, and 116 mm high, weighing 1.45 kg. Rated operational voltage of the main circuit is 1000 V. Conventional free-air thermal current is 125 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC96-30-00-42
ABB AFC96-30-00-42 AC contactor, manufacturer ID 1SBL401001R4200. It has three normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 130 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C; 80 A at 500 V; and 57 A at 690 V. Rated operational power AC-3 is 55 kW at 415 V, 440 V, 500 V, and 690 V; 45 kW at 380/400 V; and 25 kW at 220/230/240 V. Dimensions are 70 mm wide, 119.5 mm deep, 116 mm high, 1.21 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC96-30-00-51
ABB AC contactor AFC96-30-00-51, manufacturer ID 1SBL401001R5100. Three main contacts, normally open, no auxiliary contacts. Main circuit rated operational voltage 1000 V; rated frequency 50/60 Hz for main and auxiliary circuits. Conventional free-air thermal current 130 A per IEC 60947-4-1, open contactors, 40 °C. Rated operational current AC-3: 96 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C; 80 A at 500 V; 57 A at 690 V. Rated operational power AC-3: 55 kW at 415 V, 440 V, 500 V, and 690 V; 45 kW at 380/400 V; 25 kW at 220/230/240 V. Dimensions 70 mm wide, 119.5 mm deep, 116 mm high; 1.21 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC96-30-00-80
ABB AFC96-30-00-80 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.21 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 130 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 80 A at 500 V, and 57 A at 690 V, all at 60 °C. Rated operational power AC-3 is 55 kW at 415 V, 440 V, 500 V, and 690 V, 45 kW at 380/400 V, and 25 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.