- AF09-30-01K-14
ABB AF09-30-01K-14 is a 3-pole AC contactor, manufacturer ID 1SBL137005R1401. It has three normally open main contacts and one normally closed auxiliary contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, AC-3 ratings include 9 A at 380/400 V and 415 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C; corresponding AC-3 power is 4 kW at 380/400 V and 415 V, and 5.5 kW at 500 V and 690 V. AC-1 current is 25 A at 690 V and 40 °C or 60 °C. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; weight 0.325 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF09-30-10-11
The ABB AF09-30-10-11 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 400 V and 5.5 kW at 500 V and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF09-30-10-12
The ABB AF09-30-10-12 is a non-reversing AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 35 A at 40 °C. AC-3 ratings include 9 A at 415 V and 60 °C, and 7 A at 690 V and 60 °C, corresponding to 4 kW at 400 V and 5.5 kW at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF09-30-10-13
The ABB AF09-30-10-13 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. The rated control circuit voltage is 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. Rated operational voltage is 690 V for both main and auxiliary circuits. Rated operational power AC-3 is 4 kW at 400 V and 5.5 kW at 500 V and 690 V. It complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Terminals are screw type, IP20, with 10 mm stripping length. DIN-rail mounting is TH35-15 or TH35-7.5 per IEC 60715.
- AF09-30-10-13LU
The ABB AF09-30-10-13LU is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. The contactor is rated for auxiliary and main circuits up to 690 V at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 400 V and 5.5 kW at 500 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF09-30-10-14
ABB AF09-30-10-14 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 400 V and 5.5 kW at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID 1SBL137001R1410.
- AF09-30-10-14LU
The ABB AF09-30-10-14LU is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, at 60 °C. Rated operational power AC-3 is 4 kW at 400 V and 5.5 kW at 500 V and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF09-30-10K-11
The ABB AF09-30-10K-11 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It is identified by manufacturer ID 1SBL137005R1110. The contactor is rated 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz across auxiliary, control, and main circuits. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, 7 A at 690 V, and 9 A at 380/400 V and 220/230/240 V, all at 60 °C. Corresponding AC-3 rated operational power is 4 kW at 415 V, 440 V, and 380/400 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Net dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight is 0.285 kg.