Product Model
OT400E04WP
Material Number
1SCA022809R8810
Manufacturer
ABB
Product ID
85669

Get a Free Quote

Request pricing and availability for OT400E04WP.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
Front IP00
Product Net Weight
4.3 kg 9.6 lb
Rated Conditional Short-Circuit Current (Inc)
(500 A fuse, 500 V) 100 kA (500 A fuse, 690 V) 80 kA
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 132 kW (400 ... 415 V) 230 kW (500 V) 280 kW (690 V) 400 kW
See all specifications

Product Highlights

  1. Electrical Ratings: 4-pole switch-disconnector rated 400 A at 380 to 690 V AC in AC-21A, AC-22A, and AC-23A, with a rated operational voltage of 1000 V and rated insulation voltage of 1000 V per IEC/EN 60664-1
  2. Switching and Short-Circuit Capability: Rated impulse withstand voltage 12 kV, rated short-circuit making capacity 65 kA at 690 V, rated conditional short-circuit current 100 kA at 500 V and 80 kA at 690 V with a 500 A fuse, and rated short-time withstand current 15 kA for 1 s
  3. Configuration and Mounting: Base mounting with front operation, mechanism at the left end of the switch, line terminals top in/bottom out or bottom in/top out, wide phase distance, and a switched fourth pole on the right side with simultaneous function
  4. Terminals and Torque: Lug terminals 25 mm wide with tightening torque 30 to 44 N·m per IEC 60947-1
  5. Dimensions and Durability: 275 mm wide, 185 mm high, 107 mm deep, 4.3 kg, front IP00, pollution degree 3, mechanical durability 16000 operating cycles, and 10 W power loss per pole at rated operating conditions
OT400E04WP

Product Information

Technical Specifications

Specifications for OT400E04WP

ParameterValue
Degree of ProtectionFront IP00
Environmental Information1SCC301266D0201
Pollution Degree3
Product Net Width275 mm
Product Net Height185 mm
Product Net Depth / Length107 mm
Product Net Weight4.3 kg 9.6 lb
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 400 A
Conventional Thermal Current (Ithe)Fully Enclosed 400 A
Degree of ProtectionFront IP00
Distance Between PhasesWide phase distance
Fourth Pole PositionRight Side
Fourth Pole TypeSwitched - Simultaneous Function
Handle ColorBlack
Handle TypeHandle and shaft included
Lock TypeYes
Mechanical Durability16000
Mounting TypeBase mounting
Number of Poles4P
Operating ModeFront operated
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out Bottom In - Top Out
Power Lossat Rated Operating Conditions per Pole 10 W
Rated Conditional Short-Circuit Current (Inc)(500 A fuse, 500 V) 100 kA (500 A fuse, 690 V) 80 kA
Rated Impulse Withstand Voltage (Uimp)12 kV
ParameterValue
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-21A (Ie)(380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A
Rated Operational Power AC-23A (Pe)(220 ... 240 V) 132 kW (400 ... 415 V) 230 kW (500 V) 280 kW (690 V) 400 kW
Rated Operational VoltageMain Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)(690 V) 65 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 15 kA
Special FunctionsWide phase distance
StandardsIEC 60947-3
Switches Operating MechanismMechanism at the End of the Switch 04 (Left Side)
Terminal TypeLug terminals
Terminal Width25 mm
Tightening Torqueacc. IEC 60947-1 30 … 44 N·m
Tightening Torqueacc. IEC 60947-1 30 … 44 N·m
Object Classification CodeQ
ETIM 8EC000216 - Switch disconnector
ETIM 9EC000216 - Switch disconnector (low voltage)
eClassV11.1 : 27371403
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)3660829
E-Number (Norway)4337060
Manufacturer ID1SCA022809R8810