- OT1250E03W4P
ABB OT1250E03W4P is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 454.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1250E03W8
The ABB OT1250E03W8 is a 3-pole, front-operated isolating switch intended for base mounting. Its conventional free-air thermal current (Ith) is 1250 A at an ambient temperature of 40 °C, and its conventional thermal current (Ithe) is 1250 A fully enclosed. Power loss is 29 W per pole at rated operating conditions. The switch has a phase distance of 185 mm, pollution degree 3, and front degree of protection IP00. Line terminals can be configured top in and bottom out, or bottom in and top out. Mechanical durability is 6000 operations. The handle and shaft are not included, and no lock is provided. Dimensions are 544.5 mm wide, 306 mm high, and 145.5 mm deep, with a net weight of 18.6 kg. Manufacturer ID: 1SCA022871R8460.
- OT1250E03W8P
ABB OT1250E03W8P is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 544.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1250E04
The ABB OT1250E04 is a four-pole isolating switch with front operation and base mounting. Its conventional free-air thermal current (Ith) is 1250 A at 40 °C, and the fully enclosed conventional thermal current (Ithe) is 1250 A. The fourth pole is on the right side and is switched with simultaneous function. Mechanical durability is 6000 cycles. The switch has front IP00 protection and pollution degree 3. Dimensions are 414.5 mm wide, 306 mm high, and 145.5 mm deep, with a net weight of 18.8 kg. A handle and shaft are not included. The manufacturer ID is 1SCA022860R5690.
- OT1250E04C
ABB isolating switch OT1250E04C, 4-pole, front-operated, base mounting. Conventional free-air thermal current Ith is 1250 A at 40 °C. Rated insulation voltage Ui is 1000 V; rated impulse withstand voltage Uimp is 12 kV. Rated operational current is 1250 A at 380–415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A; AC-31B and AC-33B are 1250 A at 380–415 V. Rated operational power AC-23A is 710 kW at 380–415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated short-time withstand current Icw is 50 kA rms for 1 s. Front degree of protection is IP20; pollution degree 3. Screw terminals, 50 mm width, tightening torque 50 to 75 N·m per IEC 60947-1. Fourth pole right side, switched simultaneous function. Handle and shaft not included. Net weight 41.67 kg.
- OT1250E04CK
ABB OT1250E04CK is a 4-pole, front-operated, base-mounted isolating switch with a direct-mounted black handle and screw terminals. It is rated 1250 A at 40 °C conventional free-air thermal current, with rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, and rated operational voltage 1000 V for the main circuit. Rated operational current is 1250 A at 380–415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A, and 1250 A at 380–415 V for AC-31B and AC-33B. Rated operational power AC-23A is 710 kW at 380–415 V, 900 kW at 500 V, and 1200 kW at 690 V. Short-time withstand current is 50 kA rms for 1 s. Front degree of protection is IP20, pollution degree 3. Dimensions are 480 mm wide, 306 mm high, and 309 mm deep; net weight 42.36 kg. Tightening torque is 50 to 75 N·m according to IEC 60947-1.
- OT1250E04CP
The ABB OT1250E04CP is a four-pole, front-operated isolating switch for base mounting, with a black handle and shaft included. Its conventional free-air thermal current (Ith) is 1250 A at 40 °C. Rated insulation voltage (Ui) is 1000 V, rated impulse withstand voltage (Uimp) is 12 kV, and rated short-time withstand current (Icw) is 50 kA rms for 1 s. Rated operational current is 1250 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A; AC-31B and AC-33B are rated 1250 A at 380 to 415 V. Rated operational power AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Terminals are screw type, 50 mm wide, tightened to 50 to 75 N·m per IEC 60947-1. Net dimensions are 480 mm wide, 306 mm high, and 309 mm deep; net weight is 42.52 kg.
- OT1250E04K
ABB OT1250E04K is a four-pole isolating switch-disconnector, manufacturer ID 1SCA108357R1001. It is front-operated and base-mounted, with a direct-mounted pistol-type black handle and a lockable mechanism. The fourth pole is on the right side and is switched with simultaneous function. Rated conventional free-air thermal current Ith is 1250 A at 40 °C; conventional thermal current Ithe is 1250 A fully enclosed. Mechanical durability is 6000 operations. Pollution degree 3 applies. Front degree of protection is IP00. Dimensions are 414.5 mm width, 306 mm height, and 167 mm depth; net weight is 19.7 kg. Phase distance is standard.