- AF65-30-00-13
The ABB AF65-30-00-13 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 111 mm deep, and 125.5 mm high, and weighs 0.95 kg. The main circuit is rated 690 V at 50/60 Hz; the control circuit operates at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 105 A at 40 °C. AC-3 ratings include 65 A at 380/400 V and 30 kW at 400 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22. Manufacturer ID: 1SBL387001R1300.
- AF65-30-00-13LU
The ABB AF65-30-00-13LU is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 111 mm deep, and 125.5 mm high, and weighs 0.95 kg. The main circuit is rated 690 V at 50/60 Hz; the control circuit operates at 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 60 °C, 55 A at 500 V, and 39 A at 690 V. Rated operational power AC-3 is 30 kW at 400 V and 37 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF65-30-00-14
The ABB AF65-30-00-14 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a control circuit frequency of 50/60 Hz. Rated operational current AC-3 is 65 A at 415 V and 60 °C, 55 A at 500 V and 60 °C, and 39 A at 690 V and 60 °C. Rated operational power AC-3 is 30 kW at 400 V and 37 kW at 415 V. The contactor uses screw terminals, mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, and measures 55 mm wide, 111 mm deep, and 125.5 mm high, weighing 0.95 kg. Standards listed include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF65-30-00-14LU
The ABB AF65-30-00-14LU is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 111 mm deep, and 125.5 mm high, and weighs 0.95 kg. The main circuit is rated 690 V at 50/60 Hz, with a conventional free-air thermal current of 105 A according to IEC 60947-4-1 at 40 °C for open contactors. Rated operational current AC-3 is 65 A at 415 V and 440 V, 55 A at 500 V, and 39 A at 690 V, all at 60 °C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF65-30-11-11
The ABB AF65-30-11-11 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 39 A at 690 V, both at 60 °C. Rated control circuit voltage is 24 to 60 V at 50/60 Hz and 20 to 60 V DC. It carries IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22. Dimensions are 67 mm wide, 111 mm deep, and 125.5 mm high; weight is 1.01 kg.
- AF65-30-11-12
The ABB AF65-30-11-12 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 111 mm deep, and 125.5 mm high, and weighs 1.01 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 60 °C, and 39 A at 690 V and 60 °C. Rated operational power AC-3 is 30 kW at 400 V and 37 kW at 415 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF65-30-11-14
The ABB AF65-30-11-14 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 111 mm deep, and 125.5 mm high, and weighs 0.99 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational power AC-3 is 30 kW at 380/400 V and 37 kW at 415, 440, 500, and 690 V. Rated operational current AC-3 at 60 °C is 65 A at 415 V and 440 V, 55 A at 500 V, and 39 A at 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF65-30-22-12
The ABB AF65-30-22-12 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current Ith is 105 A at 40 °C for open contactors. Rated operational current AC-3 is 65 A at 415 V and 60 °C, 55 A at 500 V, and 39 A at 690 V. Rated operational power AC-3 is 30 kW at 400 V and 37 kW at 415 V. Dimensions are 55 mm wide, 144 mm deep, and 125.5 mm high; net weight is 1.02 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.