- AFC09-30-10-42
ABB AC contactor AFC09-30-10-42, manufacturer ID 1SBL131001R4210. It has three normally open main contacts, no normally closed main contacts, and one normally open auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC09-30-10-51
ABB AC contactor, model AFC09-30-10-51, manufacturer ID 1SBL131001R5110. It has three normally open main contacts, one normally open auxiliary contact, and no normally closed contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC09-30-10-80
ABB AFC09-30-10-80 is a 3-pole AC contactor with three normally open main contacts and one normally open built-in auxiliary contact. Screw terminals are used. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 9 A at 415 V and 7 A at 690 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC09-30-10-81
ABB AFC09-30-10-81 is a 3-pole AC contactor with three normally open main contacts and one normally open built-in auxiliary contact. It is rated for a 24 V control circuit at 50/60 Hz and has screw terminals. Per IEC/EN 60947-4-1, AC-3 ratings include 4 kW at 415 V and 440 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. AC-1 rated operational current is 25 A at 690 V and 40 °C or 60 °C. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.309 kg. Standards listed are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC09-30-10-84
ABB AFC09-30-10-84 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.306 kg. The contactor is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC09-30-10-85
ABB AFC09-30-10-85 is a 3-pole AC contactor, manufacturer ID 1SBL131001R8510. It has 3 normally open main contacts, 1 normally open auxiliary contact, and no normally closed contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, at 60 °C. Rated operational power AC-3 is 4 kW at 415 V and 440 V, and 5.5 kW at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC09-30-10-86
ABB AFC09-30-10-86 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. The contactor is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 9 A at 415 V and 60 °C, and 7 A at 690 V and 60 °C, with corresponding powers of 4 kW at 415 V and 5.5 kW at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC09-30-10-88
ABB AFC09-30-10-88 is a 3-pole AC contactor with three normally open main contacts and one built-in normally open auxiliary contact. It uses push-in terminals. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.303 kg. The contactor is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 9 A at 415 V and 4 kW at 415 V. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.