- CT-EBD.12
The ABB CT-EBD.12 is an electronic flasher time relay, starting with ON. It provides a time range of 0.05 s to 100 h. The rated control supply voltage is 24 to 240 V AC and 24 to 48 V DC, with a rated frequency of 50/60 Hz. The output is one changeover (SPDT) contact. Rated operational current is 6 A at 230 V AC-12, 3 A at 230 V AC-15, 6 A at 24 V DC-12, and 2 A at 24 V DC-13. The auxiliary circuit rated operational voltage is 250 V. The relay measures 17.5 mm wide, 70 mm high, and 63 mm deep, weighs 0.052 kg, and uses screw terminals. Housing protection is IP50 and terminal protection is IP20. Manufacturer ID: 1SVR500150R0000.
- CT-ERC.12
The ABB CT-ERC.12 is a single-function electronic time relay for ON-delay applications, order code 1SVR508100R0000. It provides seven adjustable time ranges from 0.05 s to 100 h. Rated control supply voltage is 24 to 240 V AC or 24 to 48 V DC, with a rated frequency of 50/60 Hz DC. The output is one changeover (SPDT) contact with screw terminals. Rated operational current is 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 12 V, 100 mA. Dimensions are 17.5 mm wide, 70 mm high, and 63 mm deep; net weight is 0.052 kg. Housing protection is IP50, terminals IP20.
- CT-ERC.22
The ABB CT-ERC.22 is an ON-delay time relay with a time range of 0.05 s to 100 h across 7 ranges. It accepts a rated control supply voltage of 24 to 240 V AC or 24 to 48 V DC, with a rated frequency of 50/60 Hz. The output consists of 2 changeover (SPDT) contacts. Rated operational current is 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 12 V, 100 mA. The relay measures 17.5 mm wide, 80 mm high, and 63 mm deep, weighs 0.068 kg, and uses screw terminals. Housing protection is IP50 and terminal protection is IP20.
- CT-ERD.12
The ABB CT-ERD.12 is a single-function ON-delay electronic time relay with a time range of 0.05 s to 100 h. It operates on a rated control supply voltage of 24 to 240 V AC or 24 to 48 V DC, with a rated frequency of 50/60 Hz DC. The output is one changeover (SPDT) contact, rated 6 A at 230 V AC-12, 3 A at 230 V AC-15, 6 A at 24 V DC-12, and 2 A at 24 V DC-13. Auxiliary circuit rated operational voltage is 250 V. The relay has screw terminals, dimensions of 17.5 mm width, 70 mm height, and 63 mm depth, and weighs 0.052 kg. Housing protection is IP50, terminals IP20. Rated impulse withstand voltage is 4 kV, rated insulation voltage 300 V, overvoltage category III, pollution degree 3. Manufacturer ID: 1SVR500100R0000.
- CT-ERD.22
The ABB CT-ERD.22 is a single-function electronic time relay with ON-delay operation and seven selectable time ranges from 0.05 s to 100 h. It provides two changeover (SPDT) contacts and accepts a rated control supply voltage of 24 to 240 V AC or 24 to 48 V DC, with a rated frequency of 50/60 Hz DC. Auxiliary circuit rated operational voltage is 250 V. Contact ratings include 5 A at 230 V AC-12, 3 A at 230 V AC-15, 5 A at 24 V DC-12, and 2 A at 24 V DC-13. The housing measures 17.5 mm wide, 80 mm high, and 63 mm deep, weighs 0.068 kg, and uses screw terminals. Protection is IP50 at the housing and IP20 at the terminals. Rated impulse withstand voltage is 4 kV, rated insulation voltage is 300 V, overvoltage category III, pollution degree 3.
- CT-ERS.12P
The ABB CT-ERS.12P is an ON-delay timer relay with a time range of 0.05 s to 300 h. Rated control supply voltage is 24 to 240 V AC and 24 to 48 V DC, with a rated frequency of 50/60 Hz DC. Output is one changeover (SPDT) contact. The relay measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, and weighs 0.101 kg. It uses screwless terminals with a wire stripping length of 8 mm and accepts 2x 0.5 to 1.5 mm² conductors. Housing protection is IP50 and terminal protection is IP20. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61812-1, and UL 508.
- CT-ERS.12S
The ABB CT-ERS.12S is a single-function electronic time relay with an ON-delay function and a time range of 0.05 s to 300 h. It is rated for a control supply voltage of 24 to 240 V AC and 24 to 48 V DC, with a rated frequency of 50/60 Hz DC. The output is one changeover (SPDT) contact. Rated operational current is 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. The relay measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighs 0.106 kg, and uses screw terminals. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61812-1, and UL 508.
- CT-ERS.21P
The ABB CT-ERS.21P is an electronic ON-delay time relay, manufacturer ID 1SVR740100R0300. It provides a time range of 0.05 s to 300 h across 10 ranges, adjusted via front-face operating elements. Rated control supply voltage is 24 to 240 V AC/DC; rated frequency is 50/60 Hz DC. Output is 2 c/o (SPDT) contacts with screwless terminals. Rated operational current is 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 12 V 100 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighing 0.121 kg. Housing protection is IP50, terminals IP20.