The ABB CA4-31NRT is a front-mounted auxiliary contact block with 3 normally open and 1 normally closed auxiliary contacts. It uses ring-tongue terminals and measures 45 mm wide, 39.8 mm deep, and 43 mm high, with a net weight of 0.05 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C, rated insulation voltage 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA, and rated impulse withstand voltage 6 kV. It is suitable for NFZB22E, NFB22E, NFZB31E, NFB31E, NFZB40E, and NFB40E. Standards: IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-10. Auxiliary terminals provide IP20 protection according to IEC 60529, IEC 60947-1, and EN 60529.
- CA4-31U
The ABB CA4-31U is a front-mounted auxiliary contact block with 3 normally open and 1 normally closed instantaneous contacts. It measures 43 mm wide, 39.5 mm deep, and 43 mm high, and weighs 0.055 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C, rated insulation voltage 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA, and rated impulse withstand voltage 6 kV. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14. Auxiliary terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529. Wire stripping length is 10 mm.
- CA4-40E
ABB CA4-40E auxiliary contact block, manufacturer ID 1SBN010140R1040. It has four normally open (NO) auxiliary contacts and no normally closed (NC) contacts. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Rated impulse withstand voltage is 6 kV. Dimensions are 43 mm wide, 39.5 mm deep, and 43 mm high; net weight 0.055 kg. Auxiliary terminals are IP20. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14.
- CA4-40EK
The ABB CA4-40EK is a front-mounted auxiliary contact block with four N.O. and zero N.C. instantaneous contacts. It uses Push-In Spring terminals with a wire stripping length of 10 mm and accepts flexible conductors with ferrule 0.5 to 2.5 mm², flexible with insulated ferrule 0.5 to 1.5 mm², flexible 0.5 to 2.5 mm², and rigid solid 1 to 2.5 mm². Auxiliary circuit ratings include 690 V rated operational voltage, 50/60 Hz rated frequency, 16 A conventional free-air thermal current at 40 °C per IEC 60947-5-1, 6 kV rated impulse withstand voltage, and IP20 protection on auxiliary terminals. It measures 43 mm wide, 39.5 mm deep, 45 mm high, and weighs 0.05 kg. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14.
- CA4-40ERT
The ABB CA4-40ERT is a front-mounted auxiliary contact block with four normally open (NO) auxiliary contacts and no normally closed (NC) contacts. It uses ring-tongue terminals with a tightening torque of 11 in·lb for the auxiliary circuit. Dimensions are 45 mm width, 39.8 mm depth, and 43 mm height, with a net weight of 0.05 kg. It is suitable for AF09B, AF09ZB, AF12B, AF12ZB, AF16B, AF16ZB, AF26B, AF26ZB, AF30B, AF30ZB, AF38B, and AF38ZB contactors. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Standards: IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-10.
- CA4-40N
ABB CA4-40N auxiliary contact block with four normally open (NO) auxiliary contacts and no normally closed contacts. It uses screw terminals and measures 43 mm wide, 39.5 mm deep, and 43 mm high, weighing 0.055 kg. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz, with rated insulation voltage of 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA, and rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14. Auxiliary terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529. Suitable for NF22E, NFZ22E, NF31E, NFZ31E, NF40E, NFZ40E, NFC22E, NFC31E, NFC40E, NFZB22E, NFB22E, NFZB31E, NFB31E, NFZB40E, and NFB40E.
- CA4-40NK
The ABB CA4-40NK is a front-mounted auxiliary contact block with four normally open (NO) auxiliary contacts and no normally closed (NC) contacts. It uses Push-In Spring terminals for the auxiliary circuit, with a wire stripping length of 10 mm and connecting capacity for flexible, flexible-with-ferrule, and rigid solid conductors from 0.5 to 2.5 mm². Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz, with conventional free-air thermal current of 16 A according to IEC 60947-5-1 at 40 °C. It measures 43 mm wide, 39.5 mm deep, and 45 mm high, and weighs 0.05 kg. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14. Auxiliary terminals are IP20.
- CA4-40U
The ABB CA4-40U is a 4-pole front-mounted auxiliary contact block with four normally open (NO) and zero normally closed (NC) auxiliary contacts. It uses screw terminals and measures 43 mm wide, 39.5 mm deep, and 43 mm high, weighing 0.055 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C, rated insulation voltage 690 V per IEC 60947-5-1 and 600 V per UL/CSA, and rated impulse withstand voltage 6 kV. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14. Auxiliary terminals provide IP20 protection per IEC 60529, IEC 60947-1, and EN 60529.