- AF190-30-11-14
The ABB AF190-30-11-14 is a 3-pole non-reversing AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 105 mm wide, 152 mm deep, and 196 mm high, and weighs 2.4 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 55 °C, 135 A at 690 V and 55 °C, and 85 A at 1000 V and 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 132 kW at 690 V. Manufacturer ID: 1SFL487002R1411.
- AF190-30-11-31
The ABB AF190-30-11-31 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 60 °C, and rated operational power AC-3 is 90 kW at 415 V and 90 kW at 380/400 V. Dimensions are 105 mm wide, 165.5 mm deep, and 196 mm high, with a net weight of 2.4 kg. Manufacturer ID: 1SFL487002R3111.
- AF190-30-11-32
ABB AF190-30-11-32 AC contactor, manufacturer ID 1SFL487002R3211. Three main contacts NO, zero NC, plus one auxiliary NO and one NC. Main circuit rated 1000 V at 50/60 Hz. Conventional free-air thermal current per IEC 60947-4-1 for open contactors at 40 °C is 275 A. Rated operational current AC-1: 275 A at 690 V and 40 °C, 250 A at 690 V and 60 °C, 200 A at 690 V and 70 °C. AC-3 ratings include 190 A at 415 V and 60 °C, 135 A at 690 V and 60 °C, and 85 A at 1000 V and 60 °C. AC-3 rated power at 415 V is 90 kW and at 690 V is 132 kW. Dimensions: 105 mm wide, 165.5 mm deep, 196 mm high; net weight 2.4 kg.
- AF190-30-11-33
The ABB AF190-30-11-33 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 190 A at 415 V and 55 °C, and 85 A at 1000 V and 55 °C, with rated operational power of 90 kW at 415 V and 110 kW at 1000 V. Dimensions are 105 mm wide, 169.5 mm deep, and 196 mm high; net weight is 2.4 kg. Manufacturer ID: 1SFL487002R3311.
- AF190-30-11-34
The ABB AF190-30-11-34 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 105 mm wide, 169.5 mm deep, and 196 mm high, and weighs 2.4 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 55 °C, 156 A at 500 V and 55 °C, and 85 A at 1000 V and 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 132 kW at 690 V. Manufacturer ID: 1SFL487002R3411.
- AF190-30-11-42
The ABB AF190-30-11-42 is a three-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 440 V, 156 A at 500 V, 135 A at 690 V, and 85 A at 1000 V, each at 60 °C. Rated operational power AC-3 is 90 kW at 415 V, 110 kW at 440 V, 500 V, and 1000 V, and 132 kW at 690 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg.
- AF190-30-11-43
The ABB AF190-30-11-43 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz, with a rated impulse withstand voltage of 8 kV. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 190 A at 415 V and 60 °C, and AC-3 rated operational power is 90 kW at 415 V. The control circuit is rated 220 to 240 V at 50 Hz and 60 Hz. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg.
- AF190-30-22-11
The ABB AF190-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 105 mm wide, 152 mm deep, and 196 mm high, and weighs 2.4 kg. The main circuit is rated for 1000 V at 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 55 °C, and rated operational power AC-3 is 90 kW at 415 V. The manufacturer ID is 1SFL487002R1122.