- AFC96-30-11-34
ABB AFC96-30-11-34 is a non-reversing AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 87 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.25 kg. The main circuit is rated 1000 V, with 50/60 Hz rated frequency for both main and auxiliary circuits. Rated operational current AC-3 is 96 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 80 A at 500 V, and 57 A at 690 V. Rated operational power AC-3 is 55 kW at 415 V, 440 V, 500 V, and 690 V, 45 kW at 380/400 V, and 25 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1. Manufacturer ID 1SBL401001R3411.
- AFC96-30-11-42
ABB AFC96-30-11-42 AC contactor, manufacturer ID 1SBL401001R4211. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V; rated frequency is 50/60 Hz for main and auxiliary circuits. Conventional free-air thermal current is 130 A per IEC 60947-4-1 at 40 °C for open contactors. AC-3 ratings include 96 A at 415 V and 57 A at 690 V, both at 60 °C. Dimensions are 87 mm wide, 119.5 mm deep, and 116 mm high; net weight 1.25 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC96-30-11-80
The ABB AFC96-30-11-80 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 87 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.25 kg. The main circuit is rated 1000 V. Rated operational current AC-3 is 96 A at 220/230/240 V, 380/400 V, 415 V, and 440 V at 60 °C, 80 A at 500 V, and 57 A at 690 V. Rated operational power AC-3 is 25 kW at 220/230/240 V, 45 kW at 380/400 V, and 55 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC96-30-11-81
The ABB AFC96-30-11-81 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 87 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.25 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 130 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 96 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 80 A at 500 V, and 57 A at 690 V, all at 60 °C. Rated operational power AC-3 is 55 kW at 415 V, 440 V, 500 V, and 690 V, 45 kW at 380/400 V, and 25 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC96-30-11-84
ABB AFC96-30-11-84 is a non-reversing AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. It measures 87 mm wide, 119.5 mm deep, and 116 mm high, weighing 1.25 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 130 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 96 A at 415 V and 60 °C, 80 A at 500 V and 60 °C, and 57 A at 690 V and 60 °C. AC-3 power ratings include 55 kW at 415 V and 45 kW at 380/400 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC96-30-11-85
ABB AFC96-30-11-85 is a 3-pole, non-reversing AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 87 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.25 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 130 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-1 rated operational current is 130 A at 690 V and 40 °C, 105 A at 60 °C, and 90 A at 70 °C. AC-3 ratings include 96 A at 415 V and 60 °C, and 57 A at 690 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC96-30-11-86
ABB AFC96-30-11-86 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 87 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.25 kg. The main circuit is rated 1000 V at 50/60 Hz; the auxiliary circuit is rated 50/60 Hz. Conventional free-air thermal current is 130 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-1 is 130 A at 690 V and 40 °C, 105 A at 60 °C, and 90 A at 70 °C. AC-3 ratings include 96 A at 415 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC96-30-11-88
ABB AFC96-30-11-88 is a non-reversing 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 87 mm wide, 119.5 mm deep, and 116 mm high, weighing 1.25 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 130 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 96 A at 415 V and 57 A at 690 V, both at 60 °C, with 55 kW at 415 V and 45 kW at 380/400 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.