- OT400DTRR6TZ
ABB OT400DTRR6TZ is a front-operated enclosed switch-disconnector in a steel sheet enclosure. It is a 6-pole device with a conventional thermal current (Ithe) of 400 A fully enclosed, rated operational voltage of 1000 V in the main circuit, and rated insulation voltage (Ui) of 1000 V acc. to IEC/EN 60664-1. Rated operational current is 400 A at 380 to 415 V, 500 V, and 690 V for AC-22A and AC-23A. Rated operational power AC-23A is 220 kW at 380 to 415 V, 280 kW at 500 V, and 355 kW at 690 V. Degree of protection is IP65 acc. to IEC 60529; pollution degree 3; housing impact resistance IK09. Enclosure dimensions are 800 mm wide, 800 mm high, and 230 mm deep; net weight 42.34 kg. Standards: IEC 60947-1, -3.
- OT400DUUR3AZ
The ABB OT400DUUR3AZ is a 3-pole isolating switch in a steel sheet enclosure, with a red/yellow pistol handle. Its degree of protection is IP65 according to IEC 60529, and the housing has an impact resistance rating of IK09. Pollution degree is 3. Conventional thermal current (Ithe) is 400 A fully enclosed. The enclosure measures 400 mm wide, 800 mm high, and 230 mm deep, and weighs 28.65 kg. Cable entry is bottom/bottom, with blank or 4x ring-flange outlets per side and knock-outs of 3x10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. Main circuit connection uses a 10 mm hole diameter screw clamp; PE terminal capacity is 4 pc, 25 to 120 mm². Mounted auxiliary contacts are 2 NO and 1 NC, with a maximum of 2 NO and 2 NC. No neutral terminal is provided.
- OT400DUUR3AZ-L21
ABB OT400DUUR3AZ-L21 is a three-pole enclosed isolating switch rated 400 A conventional thermal current (fully enclosed). Rated operational voltage is 1000 V; rated insulation voltage is 1000 V acc. to IEC/EN 60664-1. Rated operational current AC-23A is 400 A at 380–415 V, 500 V, and 690 V, with rated operational power AC-23A of 220 kW at 380–415 V, 280 kW at 500 V, and 355 kW at 690 V. Rated short-circuit making capacity is 65 kA at 690 V; rated conditional short-circuit current is 61.5 kA; rated short-time withstand current is 15 kA for 1 s. Enclosure is sheet steel, IP65 acc. to IEC 60529, IK09, 400 mm wide, 800 mm high, 230 mm deep, 29.85 kg. Standards: IEC 60947-1, -3. Two NO and one NC auxiliary contacts mounted.
- OT400DUUR3AZ-L22
ABB isolating switch OT400DUUR3AZ-L22, manufacturer ID 1SCA156609R1001, is a three-pole enclosed switch disconnector in an MSC steel sheet enclosure. Conventional thermal current is 400 A fully enclosed. Rated operational current is 400 A at 380 to 415 V, 500 V, and 690 V for AC-22A and AC-23A; rated operational power AC-23A is 220 kW at 380 to 415 V, 280 kW at 500 V, and 355 kW at 690 V. Rated insulation voltage is 1000 V per IEC/EN 60664-1, rated operational voltage 1000 V, pollution degree 3, and degree of protection IP65 per IEC 60529. Standards: IEC 60947-1 and IEC 60947-3. Dimensions are 400 mm wide, 800 mm high, and 230 mm deep; net weight 29.85 kg.
- OT400DUUR3TZ
ABB isolating switch OT400DUUR3TZ, manufacturer ID 1SCA022513R8690, supplied as a steel sheet enclosure with black pistol handle. Conventional thermal current (Ithe) is 400 A fully enclosed. Enclosure dimensions are 400 mm width, 800 mm height, and 230 mm depth; net weight is 28.65 kg. Degree of protection is IP65 acc. to IEC 60529, pollution degree 3, and housing impact resistance IK09. Cable entry is bottom/bottom, with blank or 4x ring-flange outlets and knock-outs of 3x10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. Main circuit connection uses 10 mm hole diameter screw clamps; PE terminal accepts 4 pc, 25 to 120 mm². Mounted auxiliary contacts are 2 NO and 1 NC, with maximum 2 NO and 2 NC. No neutral terminal.
- OT400DUUR3TZ-L27
The ABB OT400DUUR3TZ-L27 is a front-operated enclosed switch-disconnector in an MSC steel sheet enclosure. It is a 3-pole device with a pistol handle in black and no neutral terminal. Conventional thermal current (Ithe) is 400 A fully enclosed. Rated operational current is 400 A at 380 to 415 V, 500 V, and 690 V for AC-22A and AC-23A. Rated operational power AC-23A is 220 kW at 380 to 415 V, 280 kW at 500 V, and 355 kW at 690 V. Rated insulation voltage is 1000 V acc. to IEC/EN 60664-1. Rated conditional short-circuit current is 61.5 kA; rated short-circuit making capacity is 65 kA at 690 V. Degree of protection is IP65 acc. to IEC 60529. Standards: IEC 60947-1, -3.
- OT400DUUR3TZ-L28
ABB isolating switch OT400DUUR3TZ-L28, manufacturer ID 1SCA152444R1001, supplied in an MSC-type steel sheet enclosure with IP65 protection according to IEC 60529 and housing impact resistance IK09. It uses a black pistol handle and downward cable entry, with a blank side and a 4-ring flange side having knock-outs of 3x10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. Main circuit connection is by 10 mm hole screw clamp, with PE terminal 4 pc, 25 to 120 mm². Conventional thermal current Ithe is 400 A fully enclosed. Mounted auxiliary contacts are 2 NO and 1 NC, with a maximum of 2 NO and 2 NC. Mechanical durability is 16000 operations. Pollution degree 3. No neutral terminal. Dimensions are 400 mm wide, 800 mm high, and 230 mm deep; net weight 29.85 kg.
- OT400DUUR3TZ-L29
ABB isolating switch OT400DUUR3TZ-L29, manufacturer ID 1SCA152445R1001, in an MSC-type steel sheet enclosure measuring 400 mm wide, 800 mm high, and 230 mm deep, with a net weight of 29.85 kg. It is rated for a conventional thermal current (Ithe) of 400 A fully enclosed and provides IP65 protection according to IEC 60529, with pollution degree 3 and housing impact resistance IK09. The enclosure has a black pistol handle, cable entry down/down, and cable outlets per side of blank / 4x ring-flange with knock-outs of 3x10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. Main circuit connection uses a 10 mm hole diameter screw clamp, with a PE terminal for 4 pc, 25 to 120 mm². Mounted auxiliary contacts are 2 NO and 1 NC, with a maximum of 2 NO and 2 NC. Mechanical durability is 16000. No neutral terminal is included.