- NFZ62E-21 24-60V50/60HZ 20-60VDC
ABB NFZ62E-21 24-60V50/60HZ 20-60VDC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 8-pole, Contacts configuration: NC x2 + NO x6, and Control voltage1: 24...60V AC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NFZ62E-22
The ABB NFZ62E-22 is an intermediate relay with six normally open (NO) and two normally closed (NC) auxiliary contacts. Its rated control circuit voltage is 48 to 130 V at 50 Hz, 60 Hz, or DC. The relay measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.36 kg. It mounts on TH35-15 (35 x 15 mm) or TH35-7.5 (35 x 7.5 mm) DIN rails according to IEC 60715. The rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. The rated impulse withstand voltage is 6 kV. It conforms to IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, and CSA C22.2 No. 14-13.
- NFZ62E-22 48-130V50/60HZ-DC
ABB NFZ62E-22 48-130V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 8-pole, Contacts configuration: NC x2 + NO x6, and Control voltage1: 48...130V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NFZ62E-23
ABB NFZ62E-23 intermediate relay, manufacturer ID 1SBH136001R2362, for switching auxiliary and control circuits. It has 6 NO and 2 NC auxiliary contacts. The control circuit accepts 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. Auxiliary circuit rated operational voltage is 690 V; rated frequency is 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA, with 6 kV rated impulse withstand voltage. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.36 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NFZ62E-23 100-250V50/60HZ-DC
ABB NFZ62E-23 100-250V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 8-pole, Contacts configuration: NC x2 + NO x6, and Control voltage1: 100...250V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NFZ62E-30
The ABB NFZ62E-30 is an intermediate relay with six normally open and two normally closed auxiliary contacts. Its coil operates at 24 V DC, and connection is via screw terminals. The relay measures 45 mm wide, 130.5 mm deep, and 86 mm high, and weighs 0.49 kg. It mounts on TH35-15 (35 x 15 mm) or TH35-7.5 (35 x 7.5 mm) DIN rail per IEC 60715. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Standards cited are IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, and CSA C22.2 No. 14-13.
- NFZ62EK-20
The ABB NFZ62EK-20 is an intermediate relay with manufacturer ID 1SBH136005R2062. It has 6 normally open and 2 normally closed auxiliary contacts. The rated control circuit voltage for DC operation is 12 to 20 V. Rated operational voltage is 690 V for both auxiliary and main circuits, with a rated frequency of 50/60 Hz for the auxiliary circuit. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA, with rated impulse withstand voltage of 6 kV. It measures 45 mm wide, 110.5 mm deep, 92.3 mm high, and weighs 0.36 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, and CSA C22.2 No. 14-13.
- NFZ62EK-21
ABB NFZ62EK-21 intermediate relay, manufacturer ID 1SBH136005R2162. It has 6 normally open and 2 normally closed auxiliary contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high, with a net weight of 0.36 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Control circuit voltage is 24 to 60 V at 50/60 Hz and 20 to 60 V DC. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.