Industrial Automation Parts. Prompt replies from real people.

ABB NFZB40E-21 Reliable 20-60 VDC Contactor Relay

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB NFZB40E-21?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB NFZB40E-21 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
NFZB40E-21
Material Number
1SBH136061R2140
Manufacturer
ABB
Product ID
84955

Get a Free Quote

Request pricing and availability for NFZB40E-21.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.31 kg
Rated Operational Voltage
Auxiliary Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Rated Operational Current AC-15 (Ie)
(500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)
for 0.1 s 140 A for 1 s 100 A
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
See all specifications

Product Highlights

  1. Contact Configuration: 4 normally open (NO) auxiliary contacts and 0 normally closed (NC) contacts
  2. Electrical Ratings: 690 V rated operational voltage, 16 A conventional free-air thermal current at 40 °C, 6 kV rated impulse withstand voltage, and 100 A short-time withstand current for 1 s
  3. Coil and Switching: Rated control circuit voltage 24 to 60 V at 50/60 Hz or 20 to 60 V DC, with maximum switching frequencies of 6000 mechanical cycles per hour, 1200 AC-15 cycles per hour, and 900 DC-13 cycles per hour
  4. Mounting and Connection: DIN rail mounting per IEC 60715 (TH35-15 or TH35-7.5) or diagonal M4 screw mounting, screw terminals with 0.75 to 2.5 mm² connecting capacity and 10 mm wire stripping length for the control circuit
  5. Standards and Operating Conditions: Complies with IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, IEC 61373, and applicable parts of IEC 60077-1, IEC 60077-2, EN 50155, and TR CU 001/2011, with an operating ambient temperature range of -40 to +70 °C and maximum operating altitude of 3000 m without derating
NFZB40E-21

Product Information

Technical Specifications

Specifications for NFZB40E-21

ParameterValue
Product Net Width45 mm
Product Net Depth / Length77 mm
Product Net Height86 mm
Product Net Weight0.31 kg
Number of Auxiliary Contacts NO4
Number of Auxiliary Contacts NC0
StandardsIEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 5060 Hz Control Circuit 5060 Hz Main Circuit 5060 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A (690 V) 2 A (24127 V) 6 A (220240 V) 4 A (400440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A for 1 s 100 A
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour (DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)(24 V) 6 A144 W (48 V) 2.8 A134 W (72 V) 1 A72 W (110 V) 0.55 A60 W (125 V) 0.55 A69 W (220 V) 0.27 A60 W (250 V) 0.27 A68 W (400 V) 0.15 A60 W (500 V) 0.13 A65 W (600 V) 0.1 A60 W
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 690 V acc. to UL/CSA 600 V
ParameterValue
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms Between Coil De-energization and NO Contact Opening 11 ... 95 ms Between Coil Energization and NC Contact Opening 38 ... 90 ms Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 screws placed diagonally
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthControl Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal TypeScrew Terminals
Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb Control Circuit 11 in·lb
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeK
ETIM 7EC000196 - Contactor relay
ETIM 8EC000196 - Contactor relay
ETIM 9EC000196 - Contactor relay
eClassV11.0 : 27371001
UNSPSC39121529
IDEA Granular Category Code (IGCC)4763 >> Power contactor, DC switching
Manufacturer ID1SBH136061R2140

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp