Industrial Automation Parts. Prompt replies from real people.

ABB OT400DLCC3TZ Safety Switch

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the ABB OT400DLCC3TZ?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB OT400DLCC3TZ cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
OT400DLCC3TZ
Material Number
1SCA022281R6070
Manufacturer
ABB
Product ID
84895

Get a Free Quote

Request pricing and availability for OT400DLCC3TZ.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
acc. to IEC 60529 IP65
Product Net Weight
24.85 kg
Rated Conditional Short-Circuit Current (Inc)
61.5 kA
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Power AC-23A (Pe)
(380 ... 415 V) 220 kW (500 V) 280 kW (690 V) 355 kW
Rated Operational Voltage
Main Circuit 1000 V
See all specifications

Product Highlights

  1. Electrical Ratings: 3-pole isolating switch rated 400 A at 380 to 690 V AC-22A and AC-23A, with 1000 V rated insulation voltage and 1000 V rated operational voltage for the main circuit
  2. Switching Capacity: Rated operational power 220 kW at 380 to 415 V, 280 kW at 500 V and 355 kW at 690 V AC-23A, rated conditional short-circuit current 61.5 kA, rated short-circuit making capacity 65 kA at 1000 V AC and rated short-time withstand current 15 kA for 1 s
  3. Enclosure and Protection: Steel sheet enclosure with IP65 protection to IEC 60529, IK09 impact resistance and pollution degree 3, measuring 400 mm wide, 800 mm high and 230 mm deep
  4. Auxiliary Contacts: Two normally open and one normally closed auxiliary contacts mounted, with capacity for up to 2 NO and 2 NC auxiliary contacts
  5. Terminations and Cable Entry: Top line in and bottom out, top or bottom cable entry with two C-flange outlets per side and 10 mm, 12.5 mm, 20.5 mm, 25.5 mm and 32.5 mm knock-outs, main circuit screw clamp terminals with 10 mm hole diameter and 44 N·m tightening torque, plus four PE terminals for 25 to 120 mm²
  6. Compliance and Control: Conforms to IEC 60947-1 and IEC 60947-3, fitted with a black pistol handle, no neutral terminal and 10 W power loss per pole at rated operating conditions
OT400DLCC3TZ

Product Information

Technical Specifications

Specifications for OT400DLCC3TZ

ParameterValue
Degree of Protectionacc. to IEC 60529 IP65
Pollution Degree3
Product Net Width400 mm
Product Net Height800 mm
Product Net Depth / Length230 mm
Product Net Weight24.85 kg
Cable Entry PositionTop/Bottom
Cable Outlets Per Side2xC-flange / 2xC-flange, Knock-outs: 10mm, 12.5mm, 20.5mm, 25.5mm, 32.5mm
Connecting Capacity Main CircuitHole Diameter 10 mm Screw Clamp / PE Terminal 4pc,25 ... 120 mm²
Conventional Thermal Current (Ithe)Fully Enclosed 400 A
Degree of Protectionacc. to IEC 60529 IP65
Enclosure MaterialSteel sheet
Handle ColorBlack
Handle TypePistol handle
Impact Resistance RatingHousing IK09
Maximum Mounted Auxiliary Contacts2 NO, 2 NC
Mounted Auxiliary Contacts2 NO, 1 NC
Neutral TypeNo neutral terminal
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO2
Number of Poles3P
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out
Position of PE TerminalsTop In - Bottom Out
Power Lossat Rated Operating Conditions per Pole 10 W
ParameterValue
Rated Conditional Short-Circuit Current (Inc)61.5 kA
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A
Rated Operational Power AC-23A (Pe)(380 ... 415 V) 220 kW (500 V) 280 kW (690 V) 355 kW
Rated Operational VoltageMain Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)(1000 V AC) 65 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 15 kA
Recommended Screw DriverMain Circuit M10
StandardsIEC 60947-1, -3
Tightening TorqueMain Circuit 44 N·m
Recommended Screw DriverMain Circuit M10
Tightening TorqueMain Circuit 44 N·m
Object Classification CodeQ
ETIM 8EC000216 - Switch disconnector
ETIM 9EC000216 - Switch disconnector (low voltage)
UNSPSC39122205
IDEA Granular Category Code (IGCC)5166 >> Safety switch
eClassV11.1 : 27371403
WEEE Category4. Large Equipment (Any External Dimension More Than 50 cm)
E-Number (Finland)3642729
E-Number (Sweden)3140612
Manufacturer ID1SCA022281R6070

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
ABB OT400DLCC3TZ Safety Switch - Reliable 3-Pole 415V AC23