Industrial Automation Parts. Prompt replies from real people.

ABB AF205B-40-22-14 3-Pole Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB AF205B-40-22-14?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AF205B-40-22-14 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AF205B-40-22-14
Material Number
1SFL527263R1422
Manufacturer
ABB
Product ID
84853

Get a Free Quote

Request pricing and availability for AF205B-40-22-14.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
3.3 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 275 A (1000 V) 60 °C 250 A (1000 V) 70 °C 200 A (690 V) 40 °C 350 A (690 V) 60 °C 300 A (690 V) 70 °C 240 A
Rated Operational Power AC-3 (Pe)
(415 V) 110 kW (440 V) 132 kW (500 V) 132 kW (690 V) 160 kW (1000 V) 132 kW (380 / 400 V) 110 kW (220 / 230 / 240 V) 55 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A
Maximum Mechanical Switching Frequency
300 cycles per hour
See all specifications

Product Highlights

  1. Main Contacts: 4 normally open (NO) main contacts with no normally closed (NC) main contacts
  2. Auxiliary Contacts: 2 normally open (NO) and 2 normally closed (NC) auxiliary contacts
  3. Rated Operational Voltage: Main circuit rated to 1000 V
  4. AC-3 Rating: 205 A at 380 to 440 V and 55 °C, with rated operational power from 55 kW at 220 to 240 V up to 160 kW at 690 V
  5. Control Circuit: Rated control circuit voltage 250 to 500 V at 50/60 Hz and 250 to 500 V DC
  6. Mechanical Durability: 5 million operating cycles with a maximum mechanical switching frequency of 300 cycles per hour
  7. Terminals and Dimensions: Main circuit bar terminals, 140 mm wide, 152.5 mm deep, 196 mm high, 3.3 kg
AF205B-40-22-14

Product Information

Technical Specifications

Specifications for AF205B-40-22-14

ParameterValue
Product Net Width140 mm
Product Net Depth / Length152.5 mm
Product Net Height196 mm
Product Net Weight3.3 kg
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Rated Operational VoltageMain Circuit 1000 V
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 275 A (1000 V) 60 °C 250 A (1000 V) 70 °C 200 A (690 V) 40 °C 350 A (690 V) 60 °C 300 A (690 V) 70 °C 240 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 205 A (440 V) 55 °C 205 A (380400 V) 55 °C 205 A (220230240 V) 55 °C 205 A
Rated Operational Power AC-3 (Pe)(415 V) 110 kW (440 V) 132 kW (500 V) 132 kW (690 V) 160 kW (1000 V) 132 kW (380400 V) 110 kW (220230240 V) 55 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A
Rated Operational Current DC-1 (Ie)(100 V) 1 Pole, 40 °C 350 A (100 V) 1 Pole, 60 °C 300 A (100 V) 1 Pole, 70 °C 240 A (110 V) 2 Poles in Series, 40 °C 350 A (110 V) 2 Poles in Series, 60 °C 300 A (110 V) 2 Poles in Series, 70 °C 240 A (110 V) 3 Poles in Series, 40 °C 350 A (110 V) 3 Poles in Series, 60 °C 300 A (110 V) 3 Poles in Series, 70 °C 240 A (175 V) 2 Poles in Series, 40 °C 350 A (175 V) 2 Poles in Series, 60 °C 300 A (175 V) 2 Poles in Series, 70 °C 240 A (200 V) 2 Poles in Series, 40 °C 350 A (200 V) 2 Poles in Series, 60 °C 300 A (200 V) 2 Poles in Series, 70 °C 240 A (220 V) 3 Poles in Series, 40 °C 350 A (220 V) 3 Poles in Series, 60 °C 300 A (220 V) 3 Poles in Series, 70 °C 240 A (260 V) 3 Poles in Series, 40 °C 350 A (260 V) 3 Poles in Series, 60 °C 300 A (260 V) 3 Poles in Series, 70 °C 240 A (300 V) 3 Poles in Series, 40 °C 350 A (300 V) 3 Poles in Series, 60 °C 300 A (300 V) 3 Poles in Series, 70 °C 240 A (350 V) 4 Poles in Series, 40 °C 350 A (350 V) 4 Poles in Series, 60 °C 300 A (350 V) 4 Poles in Series, 70 °C 240 A (400 V) 4 Poles in Series, 40 °C 350 A (400 V) 4 Poles in Series, 60 °C 300 A (400 V) 4 Poles in Series, 70 °C 240 A (72 V) 1-Pole, 40 °C 350 A (72 V) 1-Pole, 60 °C 300 A (72 V) 1-Pole, 70 °C 240 A (72 V) 2 Poles in Series, 40 °C 350 A (72 V) 2 Poles in Series, 60 °C 300 A (72 V) 2 Poles in Series, 70 °C 240 A (72 V) 3 Poles in Series, 40 °C 350 A (72 V) 3 Poles in Series, 60 °C 300 A (72 V) 3 Poles in Series, 70 °C 240 A (90 V) 1 Pole, 40 °C 350 A (90 V) 1 Pole, 60 °C 300 A (90 V) 1 Pole, 70 °C 240 A
ParameterValue
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 275 A (110 V) 2 Poles in Series, 60 °C 275 A (110 V) 2 Poles in Series, 70 °C 240 A (110 V) 3 Poles in Series, 40 °C 275 A (110 V) 3 Poles in Series, 60 °C 275 A (110 V) 3 Poles in Series, 70 °C 240 A (220 V) 3 Poles in Series, 40 °C 275 A (220 V) 3 Poles in Series, 60 °C 275 A (220 V) 3 Poles in Series, 70 °C 240 A (72 V) 2 Poles in Series, 40 °C 275 A (72 V) 2 Poles in Series, 60 °C 275 A (72 V) 2 Poles in Series, 70 °C 240 A (72 V) 3 Poles in Series, 40 °C 275 A (72 V) 3 Poles in Series, 60 °C 275 A (72 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 275 A (110 V) 2 Poles in Series, 60 °C 275 A (110 V) 2 Poles in Series, 70 °C 240 A (110 V) 3 Poles in Series, 40 °C 275 A (110 V) 3 Poles in Series, 60 °C 275 A (110 V) 3 Poles in Series, 70 °C 240 A (220 V) 3 Poles in Series, 40 °C 275 A (220 V) 3 Poles in Series, 60 °C 275 A (220 V) 3 Poles in Series, 70 °C 240 A (72 V) 2 Poles in Series, 40 °C 275 A (72 V) 2 Poles in Series, 60 °C 275 A (72 V) 2 Poles in Series, 70 °C 240 A (72 V) 3 Poles in Series, 40 °C 275 A (72 V) 3 Poles in Series, 60 °C 275 A (72 V) 3 Poles in Series, 70 °C 240 A
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz / 60 Hz 250 ... 500 V DC Operation 250 ... 500 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 260 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 260 V·A Pull-in at Max. Rated Control Circuit Voltage DC 230 W
Terminal TypeMain Circuit: Bars
General Use Rating UL/CSA(600 V AC) 250 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 30 Hp (200 V AC) Three Phase 60 hp (208 V AC) Three Phase 60 hp (220 ... 240 V AC) Three Phase 30 Hp (220 ... 240 V AC) Three Phase 75 hp (440 ... 480 V AC) Three Phase 75 Hp (440 ... 480 V AC) Three Phase 150 hp (550 ... 600 V AC) Three Phase 100 Hp (550 ... 600 V AC) Three Phase 200 hp
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
E-Number (Sweden)3210475
Manufacturer ID1SFL527263R1422

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp