- OT16F3U/B50
ABB OT16F3U/B50 is a 3-pole non-fusible isolating switch. Rated operational current AC-22A is 16 A at 380 to 415 V, 500 V, and 690 V; AC-23A is 16 A at 380 to 415 V and 500 V, and 10 A at 690 V. Rated operational power AC-23A is 3 kW at 220 to 240 V, and 7.5 kW at 400 to 415 V, 500 V, and 690 V. Rated insulation voltage is 750 V acc. to IEC/EN 60664-1; rated impulse withstand voltage is 8 kV. Conventional thermal current is 25 A fully enclosed. Standards: IEC 60947-3, UL 508, CSA C22.2 No. 14. Front degree of protection IP20, pollution degree 3, screw terminals, 0.8 N·m tightening torque acc. IEC 60947-1. Dimensions 35 x 68 x 56 mm. Knob handle and shaft not included.
- OT16F4C
ABB OT16F4C is a 4-pole, front-operated isolating switch with open transition, rated 16 A. It is base mounting with screw terminals and accepts cable cross-sections from 0.75 to 10 mm². Rated insulation voltage is 750 V, rated impulse withstand voltage is 8 kV, and rated short-time withstand current is 0.5 kA rms for 1 s. Conventional free-air thermal current is 25 A at 40 °C; fully enclosed thermal current is 25 A. Power loss is 0.3 W per pole at rated operating conditions. Front degree of protection is IP20, pollution degree 3. Standards: UL 98 and IEC 60947-3. Tightening torque is 0.8 N·m according to IEC 60947-1. Handle and shaft are not included. Net weight is 0.31 kg.
- OT16F4N1
The ABB OT16F4N1 is a four-pole isolating switch with base mounting and front operation. It has a rated insulation voltage of 750 V according to IEC/EN 60664-1 and a rated impulse withstand voltage of 8 kV. Rated operational current is 16 A at 380 to 415 V, 500 V, and 690 V for AC-21A and AC-22A; for AC-23A it is 16 A at 380 to 415 V and 500 V, and 10 A at 690 V. Conventional free-air thermal current is 25 A at 40 degrees C, and fully enclosed thermal current is 25 A. Dimensions are 48 mm wide, 68 mm high, and 56 mm deep, weighing 0.125 kg. It uses screw terminals for Cu cable cross-sections from 0.75 to 10 mm². Standards: IEC 60947-3, UL 508, CSA C22.2 No. 14.
- OT16F4N2
ABB OT16F4N2 is a 4-pole, front-operated, non-fusible switch-disconnector. The fourth pole is on the right side and is switched with simultaneous function. It is base-mounting, with dimensions of 48 mm width, 68 mm height, and 56 mm depth, and a net weight of 0.125 kg. The front degree of protection is IP20, with pollution degree 3. Conventional free-air thermal current Ith is 25 A at 40 °C; conventional thermal current Ithe is 25 A fully enclosed. Main-circuit connecting capacity includes Cu 0.75 to 10 mm² flexible, 0.75 to 6 mm² solid, and 0.75 to 4 mm² flexible with ferrule. Mechanical durability is 20000 operations. A knob handle and shaft are not included. Manufacturer ID: 1SCA104829R1001.
- OT16F6
The ABB OT16F6 is a 6-pole, front-operated isolating switch with base mounting and screw terminals. It is rated 750 V in the main circuit, with a rated insulation voltage of 750 V according to IEC/EN 60664-1 and a rated impulse withstand voltage of 8 kV. Rated operational current is 16 A at 380 to 415 V, 500 V, and 690 V for AC-21A and AC-22A; for AC-23A it is 16 A at 380 to 415 V and 500 V, and 10 A at 690 V. Conventional free-air thermal current is 25 A at 40 °C, and fully enclosed thermal current is 25 A. The front degree of protection is IP20, pollution degree 3, mechanical durability 20000 operations. Standards: IEC 60947-3, UL 508, CSA C22.2 No. 14.
- OT16F8
The ABB OT16F8 is a switch-disconnector for isolating circuits. It supports panel, DIN rail, and base mounting. A range of accessories is available for configuration. The supplied catalog content does not state rated current, voltage, utilization category, or applicable standard, so these parameters are not specified here.
- OT16F8/B3
The ABB OT16F8/B3 is an 8-pole isolating switch with screw terminals. It is rated 750 V (rated operational voltage, main circuit) and 750 V rated insulation voltage according to IEC/EN 60664-1, with 8 kV rated impulse withstand voltage. Conventional thermal current is 25 A fully enclosed; rated operational current AC-22A is 16 A at 380 to 415 V, 500 V, and 690 V, and AC-23A is 16 A at 380 to 415 V and 500 V, and 10 A at 690 V. Power loss is 0.3 W per pole at rated operating conditions. Dimensions are 96 mm wide, 68 mm high, and 68 mm deep, weighing 0.27 kg. Front degree of protection is IP20, pollution degree 3, mechanical durability 20000 cycles. Standards: IEC 60947-3, UL 508, CSA C22.2 No. 14.
- OT16FT3
The ABB OT16FT3 is a 3-pole, non-fusible isolating switch with a front-operated mechanism and door mounting. It has a rated current of 16 A and is rated 600 VAC and 10 hp. The switch uses protected clamp terminals and accepts Cu cable cross-sections from 0.75 to 10 mm². Conventional free-air thermal current (Ith) is 25 A at 40 °C; conventional thermal current (Ithe) fully enclosed is 25 A. Mechanical durability is 20,000 operations. Dimensions are 43 mm wide, 54 mm high, and 52 mm deep, with a net weight of 0.1 kg. Front degree of protection is IP20, pollution degree 3. The handle and shaft are not included. Manufacturer ID: 1SCA104838R1001.