- NF51/11-12 48-130V50/60HZ-DC
ABB NF51/11-12 48-130V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 8-pole, Contacts configuration: NC x2 + NO x6, and Control voltage1: 48...130V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF51/11-13
ABB NF51/11-13 intermediate relay, manufacturer ID 1SBH137001R1359. It provides 6 normally open and 2 normally closed auxiliary contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high, with a net weight of 0.32 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13. DIN-rail mounting per IEC 60715.
- NF51/11-13 100-250V50/60HZ-DC
ABB NF51/11-13 100-250V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 8-pole, Contacts configuration: NC x2 + NO x6, and Control voltage1: 100...250V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF51/11-14
ABB NF51/11-14 intermediate relay, manufacturer ID 1SBH137001R1459, with mechanically linked auxiliary contacts. It provides 6 normally open and 2 normally closed auxiliary contacts. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA; rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13. Dimensions: 45 mm width, 110.5 mm depth, 86 mm height; net weight 0.32 kg.
- NF51/11-14 250-500V50/60HZ-DC
ABB NF51/11-14 250-500V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 8-pole, Contacts configuration: NC x2 + NO x6, and Control voltage1: 250...500V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF53E-11
The ABB NF53E-11 is an intermediate relay with manufacturer ID 1SBH137001R1153. It provides 5 normally open and 3 normally closed auxiliary contacts. The auxiliary circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 2 A at 500 V and 690 V, 6 A at 24/127 V, 4 A at 220/240 V, and 3 A at 400/440 V. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high, weighing 0.32 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF53E-11 24-60V50/60HZ 20-60VDC
ABB NF53E-11 24-60V50/60HZ 20-60VDC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 8-pole, Contacts configuration: NC x3 + NO x5, and Control voltage1: 24...60V AC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF53E-12
The ABB NF53E-12 is an intermediate relay with manufacturer ID 1SBH137001R1253. It provides 5 normally open and 3 normally closed auxiliary contacts. The rated operational voltage of the auxiliary circuit is 690 V, with a rated frequency of 50/60 Hz for both auxiliary and control circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC operation. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high, and 0.32 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, and CSA C22.2 No. 14-13. DIN-rail mounting is supported per IEC 60715.