Product Model
OT250E22P
Material Number
1SCA022721R4290
Manufacturer
ABB
Product ID
84755

Get a Free Quote

Request pricing and availability for OT250E22P.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
Front IP00
Product Net Weight
1.9 kg
Rated Conditional Short-Circuit Current (Inc)
(315 A fuse, 500 V) 100 kA (355 A fuse, 690 V) 80 kA (250 A fuse, 690 V) 100 kA
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 75 kW (400 ... 415 V) 145 kW (500 V) 170 kW (690 V) 250 kW
See all specifications

Product Highlights

  1. Current Rating: Conventional free-air thermal current 250 A at 40 °C and fully enclosed thermal current 250 A
  2. Rated Operational Power: AC-23A ratings of 75 kW at 220–240 V, 145 kW at 400–415 V, 170 kW at 500 V, and 250 kW at 690 V
  3. Configuration: 4-pole switch-disconnector with switched simultaneous fourth pole on the right side, front-operated mechanism between the poles, and base mounting
  4. Terminations: Lug terminals 20 mm wide with tightening torque 15–22 N·m per IEC 60947-1, line terminals usable top-in/bottom-out or bottom-in/top-out
  5. Durability and Protection: Mechanical durability 20,000 operations, front degree of protection IP00, pollution degree 3, and handle and shaft included with lockable handle
  6. Short-Circuit Withstand: Rated conditional short-circuit current 100 kA at 500 V with 315 A fuse and 100 kA at 690 V with 250 A fuse, rated short-time withstand current 8 kA for 1 s, and rated short-circuit making capacity 30 kA at 690 V
  7. Compliance: IEC 60947-3, rated insulation voltage 1000 V per IEC/EN 60664-1, and rated impulse withstand voltage 12 kV
OT250E22P

Product Information

Technical Specifications

Specifications for OT250E22P

ParameterValue
Degree of ProtectionFront IP00
Environmental Information1SCC301265D0201
Pollution Degree3
Product Net Width185.5 mm
Product Net Height150 mm
Product Net Depth / Length82.5 mm
Product Net Weight1.9 kg
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 250 A
Conventional Thermal Current (Ithe)Fully Enclosed 250 A
Degree of ProtectionFront IP00
Distance Between PhasesStandard
Fourth Pole PositionRight Side
Fourth Pole TypeSwitched - Simultaneous Function
Handle ColorBlack
Handle TypeHandle and shaft included
Lock TypeYes
Mechanical Durability20000
Mounting TypeBase mounting
Number of Poles4P
Operating ModeFront operated
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out Bottom In - Top Out
Power Lossat Rated Operating Conditions per Pole 6.5 W
Rated Conditional Short-Circuit Current (Inc)(315 A fuse, 500 V) 100 kA (355 A fuse, 690 V) 80 kA (250 A fuse, 690 V) 100 kA
Rated Impulse Withstand Voltage (Uimp)12 kV
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 1000 V
ParameterValue
Rated Operational Current AC-21A (Ie)(380 ... 415 V) 250 A (500 V) 250 A (690 V) 250 A
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 250 A (500 V) 250 A (690 V) 250 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 250 A (500 V) 250 A (690 V) 250 A
Rated Operational Power AC-23A (Pe)(220 ... 240 V) 75 kW (400 ... 415 V) 145 kW (500 V) 170 kW (690 V) 250 kW
Rated Operational VoltageMain Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)(690 V) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 8 kA
Special FunctionsNo
StandardsIEC 60947-3
Switches Operating MechanismMechanism Between the Poles 22 (Between the Poles)
Terminal TypeLug terminals
Terminal Width20 mm
Tightening Torqueacc. IEC 60947-1 15 … 22 N·m
Tightening Torqueacc. IEC 60947-1 15 … 22 N·m
Object Classification CodeQ
ETIM 8EC000216 - Switch disconnector
ETIM 9EC000216 - Switch disconnector (low voltage)
eClassV11.1 : 27371403
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)3661366
E-Number (Norway)4337861
E-Number (Sweden)3171165
Manufacturer ID1SCA022721R4290