- CA4-04NK
ABB CA4-04NK is a front-mounted auxiliary contact block with four normally closed (NC) contacts and no normally open (NO) contacts. It uses Push-In Spring terminals. Dimensions are 43 mm width, 39.5 mm depth/length, and 45 mm height; net weight is 0.05 kg. The auxiliary circuit is rated 690 V, 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14. Auxiliary terminals are IP20.
- CA4-10
The ABB CA4-10 is an auxiliary contact block with one normally open (NO) contact and no normally closed (NC) contact. It measures 9.9 mm wide, 39.5 mm deep, and 43 mm high, and weighs 0.014 kg. The auxiliary circuit is rated for 690 V operational voltage and 50/60 Hz frequency. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A at 24 V and 0.27 A at 220/250 V. Maximum mechanical switching frequency is 3600 cycles per hour. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14. Auxiliary terminals are IP20.
- CA4-10-T
ABB CA4-10-T auxiliary contact block, manufacturer ID 1SBN010110T1010. It provides one normally open (NO) auxiliary contact and no normally closed (NC) contacts. Dimensions are 9.9 mm wide, 39.5 mm deep, and 43 mm high, with a net weight of 0.014 kg. The auxiliary circuit is rated 690 V and 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14. Auxiliary terminals are IP20.
- CA4-10K
The ABB CA4-10K is a single-pole auxiliary contact block with push-in spring terminals, identified by manufacturer ID 1SBN010160R1010. It provides one auxiliary contact, NO, and no NC contact. Dimensions are 10 mm wide, 39.5 mm deep, and 45 mm high, with a net weight of 0.012 kg. The auxiliary circuit is rated 690 V, 50/60 Hz, with conventional free-air thermal current 16 A at 40 °C according to IEC 60947-5-1. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14. Auxiliary terminals are IP20.
- CA4-10K-T
ABB CA4-10K-T is a 1-pole front-mounted auxiliary contact block with one normally open (NO) auxiliary contact and no normally closed (NC) contacts. It uses Push-In Spring terminals and measures 10 mm wide, 39.5 mm deep, and 45 mm high, weighing 0.012 kg. The auxiliary circuit is rated 690 V, 50/60 Hz, with conventional free-air thermal current 16 A at 40 °C per IEC 60947-5-1. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, EN 60529.
- CA4-11
ABB auxiliary contact block CA4-11 (manufacturer ID 1SBN010110R1011) with one normally open and one normally closed auxiliary contact. It measures 43 mm wide, 19.9 mm deep, and 23.6 mm high, and weighs 0.024 kg. Auxiliary circuit ratings include 690 V rated operational voltage, 50/60 Hz rated frequency, 16 A conventional free-air thermal current according to IEC 60947-5-1 at 40 °C, 6 kV rated impulse withstand voltage, and 690 V rated insulation voltage according to IEC 60947-5-1. Screw terminals accept rigid and flexible conductors from 0.75 to 2.5 mm², with 10 mm wire stripping length. Auxiliary terminals are IP20 according to IEC 60529. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14.
- CA4-11ERT
ABB CA4-11ERT auxiliary contact block, manufacturer ID 1SBN010155R1011. It provides one normally open (NO) and one normally closed (NC) auxiliary contact, with ring-tongue terminals. Dimensions are 45 mm width, 39.8 mm depth/length, and 43 mm height; net weight 0.04 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-10. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, EN 60529. Suitable for AF09B, AF09ZB, AF12B, AF12ZB, AF16B, AF16ZB, AF26B, AF26ZB, AF30B, AF30ZB, AF38B, AF38ZB.
- CA4-11MRT
ABB CA4-11MRT auxiliary contact block with one normally open and one normally closed auxiliary contact. Rated operational voltage of the auxiliary circuit is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529, using ring-tongue terminals. Standards: IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-10. Net dimensions: 45 mm width, 39.8 mm depth, 43 mm height; 0.04 kg.