- AFC80-30-00-34
ABB AFC80-30-00-34 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 119.5 mm deep, and 116 mm high, weighing 1.21 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 130 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Corresponding AC-3 power ratings are 45 kW at 415 V, 440 V, 500 V, and 690 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC80-30-00-42
The ABB AFC80-30-00-42 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.21 kg. The main circuit is rated 1000 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 130 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 80 A at 380/400 V and 415 V at 60 °C, and 49 A at 690 V at 60 °C. Corresponding AC-3 power ratings are 37 kW at 380/400 V and 45 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC80-30-00-51
ABB AC contactor AFC80-30-00-51, manufacturer ID 1SBL391001R5100. Three main contacts, normally open, no auxiliary contacts. Rated operational voltage of the main circuit is 1000 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 130 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 415 V and 60 °C, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V. Rated operational power AC-3 is 45 kW at 415 V, 440 V, 500 V, and 690 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Dimensions are 70 mm wide, 119.5 mm deep, 116 mm high, and 1.21 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC80-30-00-80
ABB AFC80-30-00-80 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.21 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 130 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 125 A at 690 V and 40 °C, 100 A at 60 °C, and 85 A at 70 °C. AC-3 ratings include 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC80-30-00-81
ABB AFC80-30-00-81 AC contactor, manufacturer ID 1SBL391001R8100. It has three normally open main contacts and no auxiliary contacts. Main circuit rated operational voltage is 1000 V. Conventional free-air thermal current per IEC 60947-4-1 for open contactors at 40 °C is 130 A. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 440 V, 500 V, and 690 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Dimensions are 70 mm wide, 119.5 mm deep, and 116 mm high; net weight 1.21 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC80-30-00-84
ABB AFC80-30-00-84 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.21 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 130 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 125 A at 690 V and 40 °C, 100 A at 60 °C, and 85 A at 70 °C. AC-3 ratings include 80 A at 415 V and 60 °C, and 25 A at 1000 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC80-30-00-85
ABB AFC80-30-00-85 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.21 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 130 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 60 °C, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V. Rated operational power AC-3 is 37 kW at 380/400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC80-30-00-86
ABB AFC80-30-00-86 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 119.5 mm deep, and 116 mm high, weighing 1.21 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 130 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 125 A at 690 V and 40 °C, 100 A at 60 °C, and 85 A at 70 °C. AC-3 ratings include 80 A at 415 V and 60 °C, with 45 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.