- XLP00-MNS adapter-EFM-3BC
ABB fuse type isolating switch, display model XLP00-MNS adapter-EFM-3BC, manufacturer ID 1SEP101890R0412. Three-pole (3P) device for 50 mm busbar systems with front cover 3P handle and cable clamp terminals. Rated current 160 A; rated operational voltages 400 V AC, 500 V AC, and 690 V AC; rated frequency 50/60 Hz. Rated operational current AC-22B is 160 A at 500 V, AC-21B is 125 A at 690 V, and AC-23B is 125 A at 400 V. Rated conditional short-circuit current is 50 kA rms at 690 V; rated impulse withstand voltage 8 kV. Power loss 3.5 W at rated load. Fuse sizes NH00 and NH000, DIN fuse system. Degree of protection IP30. Dimensions 105 mm wide, 187 mm high, 210 mm deep; net weight 1.1 kg. Standards: IEC60947-3. Electronic fuse monitoring: No.
- XLP00-S&J-6M8
ABB XLP00-S&J-6M8 fuse type isolating switch, manufacturer ID 1SEP101890R0005. Three-pole fuse switch disconnector for NH00/NH000 DIN fuses, baseplate mounting with front cover 3P handle. Rated current 160 A; rated frequency 50/60 Hz; rated impulse withstand voltage 8 kV; rated conditional short-circuit current 50 kA rms at 690 V. Rated operational current AC-21B is 125 A at 690 V; AC-22B is 160 A at 500 V, 63 A at 800 V, and 125 A at 1000 V. Power loss at rated load 3.5 W. Dimensions 105 mm wide, 187 mm high, 90 mm deep; net weight 0.63 kg. Degree of protection IP30. Supplied with a 1.5 mm extra distance plate for S&J and six M8x16 bolts.
- XLP000-6CC
ABB XLP000-6CC is a 3-pole fuse type isolating switch with manufacturer ID 1SEP201428R0001. It accepts NH000 and NH00C fuses in a DIN fuse system and mounts on a baseplate with a 3P front cover handle. Rated current is 100 A at 50/60 Hz, with rated operational current of 50 A at 690 V AC-21B and 100 A at 500 V AC-22B. Rated impulse withstand voltage is 6 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Power loss at rated load is 1.4 W. Dimensions are 90 mm wide, 152 mm high, and 80 mm deep; net weight is 0.4 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.
- XLP000-6CC in carton
The ABB XLP000-6CC in carton is a 3-pole fuse type isolating switch disconnector with a rated current (In) of 100 A and rated operational voltages of 400 V AC, 500 V AC, and 690 V AC. It is a baseplate-mounted device with a front cover 3P handle, cable clamp terminals, and six cage clamps. Fuse size is NH000 NH00C in the DIN fuse system. Rated frequency for the main circuit is 50/60 Hz, rated impulse withstand voltage (Uimp) is 6 kV, and power loss at rated load is 1.4 W. Rated conditional short-circuit current (Inc) is 50 kiloampere rms at 690 V. Degree of protection is IP30. Standards: IEC60947-3 and GB/T14048.3. Dimensions are 95 mm width, 160 mm height, and 82 mm depth, with a net weight of 0.49 kg.
- XLP1
The ABB XLP1 is a 3-pole fuse type isolating switch with a front cover handle, mounted on a baseplate. It accepts NH1 DIN fuse links. Rated current is 250 A, with a rated operational current of 200 A at 690 V in AC-21B and 250 A at 500 V and 800 V in AC-22B. The main circuit is rated 50/60 Hz, with a rated impulse withstand voltage of 8 kV and a rated conditional short-circuit current of 50 kA rms at 690 V. Power loss is 7.5 W at rated load. Degree of protection is IP30. Dimensions are 185 mm wide, 270 mm high, and 116 mm deep; net weight is 1.6 kg. Electronic fuse monitoring is not included.
- XLP1-1P
The ABB XLP1-1P is a fuse type isolating switch, identified by manufacturer ID 1SEP600116R0001. It is a single-pole (1P) fuse switch disconnector for DIN fuse systems with NH1 fuse size, mounted on a baseplate with a front cover 1P handle. The main circuit is rated 250 A at 50/60 Hz, with a rated operational current AC-21B of 200 A at 690 V and AC-22B of 250 A at 500 V. Rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Power loss is 7.5 W at rated load. Degree of protection is IP30. Dimensions are 70 mm wide, 117 mm high, and 269 mm deep; net weight is 0.7 kg. Electronic fuse monitoring is not included.
- XLP1-1P-2BC
ABB fuse type isolating switch, model XLP1-1P-2BC, manufacturer ID 1SEP600116R0002. Single-pole (1P) fuse switch disconnector for DIN fuse system, NH1 fuse size, front cover 1P handle, baseplate mounting. Rated current 250 A; rated frequency 50/60 Hz main circuit; rated operational current AC-21B 200 A at 690 V and AC-22B 250 A at 500 V. Rated impulse withstand voltage 8 kV main circuit; rated conditional short-circuit current 50 kA rms at 690 V. Power loss 7.5 W at rated load. Degree of protection IP30. Dimensions: 70 mm width, 117 mm height, 269 mm depth. Net weight 0.82 kg. Electronic fuse monitoring: no.
- XLP1-1P-M10
The ABB XLP1-1P-M10 is a single-pole fuse type isolating switch with a rated current (In) of 250 A and a rated frequency of 50/60 Hz for the main circuit. It accepts NH1 DIN fuse links and uses bolt terminals. Rated operational voltage is 220 V DC, 500 V AC, and 690 V AC. Rated operational current is 250 A at 500 V AC (AC-22B), 200 A at 690 V AC (AC-21B), and 250 A at 220 V DC (DC-22B). Rated conditional short-circuit current is 50 kA rms at 690 V; rated impulse withstand voltage is 8 kV. Power loss is 7.5 W at rated load. Protection is IP30. Dimensions are 70 mm wide, 117 mm high, and 269 mm deep; net weight is 0.76 kg. Standards: IEC60947-3 and GB/T14048.3.