- AF09-22-00K-12
ABB AF09-22-00K-12 is an AC contactor with 2 N.O. and 2 N.C. main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.285 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 25 A at 690 V and 40 °C or 60 °C, and 22 A at 70 °C. AC-3 ratings include 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AF09-22-00K-13
The ABB AF09-22-00K-13 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz, with AC-3 operational current of 9 A at 415 V and 60 °C, and AC-3 operational power of 4 kW at 400 V. The control circuit voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC operation. It uses push-in spring terminals, mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, and measures 45 mm wide, 77 mm deep, and 92.3 mm high. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AF09-22-00K-14
The ABB AF09-22-00K-14 is an AC contactor with four poles, configured as two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.285 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-1 is 25 A at 690 V and 40 °C or 60 °C, and 22 A at 70 °C. Rated operational power AC-3 is 4 kW at 400 V, 415 V, 440 V, and 380/400 V, and 5.5 kW at 500 V and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AF09-30-01-11
The ABB AF09-30-01-11 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational power AC-3 is 4 kW at 400 V, 415 V, 440 V, and 380/400 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Rated operational current AC-3 is 9 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 9.5 A at 500 V, and 7 A at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF09-30-01-11*24-60V AC/ DC
ABB AF09-30-01-11*24-60V AC/ DC is an industrial catalog item. Key specifications include RoHS: true and Package: Box-packed. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- AF09-30-01-12
The ABB AF09-30-01-12 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-1 is 25 A at 690 V at both 40 °C and 60 °C, and 22 A at 70 °C. AC-3 ratings include 9 A at 415 V and 7 A at 690 V at 60 °C, with corresponding rated operational power of 4 kW at 400 V and 5.5 kW at 500 V and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF09-30-01-13
The ABB AF09-30-01-13 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 400 V and 5.5 kW at 500 V and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF09-30-01-14
The ABB AF09-30-01-14 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, at 60 °C. Rated operational power AC-3 is 4 kW at 400 V and 5.5 kW at 500 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL137001R1401.