- OT250E13CP
ABB OT250E13CP isolating switch, four-pole, front-operated, base mounting. Conventional free-air thermal current 250 A at 40 °C; conventional thermal current fully enclosed 250 A. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated operational voltage main circuit 1000 V. Rated operational current 250 A at 380–415 V, 500 V and 690 V for AC-21A, AC-22A and AC-23A; AC-31B and AC-33B 250 A at 380–415 V. Rated operational power AC-23A: 140 kW at 380–415 V, 170 kW at 500 V, 250 kW at 690 V. Rated short-time withstand current 8 kA rms for 1 s. Front degree of protection IP20, pollution degree 3. Screw terminals, 20 mm terminal width, tightening torque 15–22 N·m per IEC 60947-1. Fourth pole right side, switched simultaneous. Dimensions 205 x 150 x 160 mm, 3.83 kg.
- OT250E13CP-104
The ABB OT250E13CP-104 is an isolating switch with manufacturer ID 1SCA101695R1001. It handles currents from 16 A to 3200 A and is designed for operation at voltages up to 690 V AC. The switch is equipped with a long turning handle for operation.
- OT250E13P
ABB OT250E13P is a 4-pole isolating switch with a conventional thermal current (Ithe) of 250 A fully enclosed. It is rated 1000 V (main circuit), with rated insulation voltage 1000 V acc. to IEC/EN 60664-1 and rated impulse withstand voltage 12 kV. Rated operational current is 250 A at 380...415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated operational power AC-23A is 75 kW at 220...240 V, 145 kW at 400...415 V, 170 kW at 500 V, and 250 kW at 690 V. Short-circuit making capacity is 30 kA at 690 V; short-time withstand current is 8 kA for 1 s. It has lug terminals, front IP00 protection, pollution degree 3, and conforms to IEC 60947-3.
- OT250E13WCFP
ABB OT250E13WCFP is a 4-pole base-mounting switch disconnector, front operated, with the fourth pole on the right side as a switched simultaneous function. It is rated 250 A at 40 °C conventional free-air thermal current and 250 A fully enclosed, with rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, and rated operational voltage 1000 V. Rated operational currents are 250 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated operational power AC-23A is 140 kW at 380 to 415 V, 170 kW at 500 V, and 250 kW at 690 V. Short-time withstand current is 8 kA rms for 1 s. Front protection is IP20, pollution degree 3. Screw terminals, 20 mm terminal width, tightening torque 15 to 22 N·m per IEC 60947-1. Dimensions 237 x 150 x 160 mm, 4.33 kg. Handle and shaft included.
- OT250E13WCLP
ABB OT250E13WCLP isolating switch, 4-pole, front-operated, base mounting. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, conventional free-air thermal current 250 A at 40 °C, and conventional thermal current 250 A fully enclosed. Rated operational current is 250 A at 380–415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A; AC-31B and AC-33B are 250 A at 380–415 V. Rated operational power AC-23A is 140 kW at 380–415 V, 170 kW at 500 V, and 250 kW at 690 V. Short-time withstand current is 8 kA rms for 1 s. Screw terminals, tightening torque 15–22 N·m per IEC 60947-1. Dimensions 237 x 150 x 160 mm; weight 4.19 kg. Front protection IP20, pollution degree 3.
- OT250E13YP
ABB OT250E13YP is a four-pole isolating switch with base mounting and front operation. It is rated for a conventional free-air thermal current (Ith) of 250 A at 40 °C and a conventional thermal current (Ithe) of 250 A fully enclosed. The fourth pole is switched with simultaneous function and is positioned on the right side. Line terminals can be configured top in - bottom out or bottom in - top out. The front degree of protection is IP20, and the pollution degree is 3. Power loss is 6.5 W per pole at rated operating conditions. A handle and shaft are included; the handle is black. Dimensions are 229 mm wide, 150 mm high, and 236 mm deep, with a net weight of 6.05 kg. Manufacturer ID: 1SCA123571R1001.
- OT250E21
The ABB OT250E21 is a 3-pole, front-operated isolating switch for base mounting. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, with a rated impulse withstand voltage of 12 kV and rated operational voltage of 1000 V in the main circuit. Conventional free-air thermal current is 250 A at 40 °C; conventional thermal current fully enclosed is 250 A. Rated operational current is 250 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated short-time withstand current is 8 kA for 1 s, and rated short-circuit making capacity is 30 kA at 690 V. Terminal type is lug terminals; tightening torque is 15 to 22 N·m per IEC 60947-1. Standards: IEC 60947-3. Handle and shaft are not included.
- OT250E21P
ABB OT250E21P is a 3-pole, front-operated isolating switch for base mounting. It is rated 250 A conventional free-air thermal current (Ith) at 40 °C and 250 A conventional thermal current (Ithe) fully enclosed. The switch has a front degree of protection of IP00 and pollution degree 3. Dimensions are 150.5 mm width, 150 mm height, and 82.5 mm depth, with a net weight of 1.385 kg. Line terminals can be configured top in - bottom out or bottom in - top out. A black handle and shaft are included, and a lock is provided. Mechanical durability is 20000 operations. Manufacturer ID: 1SCA022731R1810.