- AF750B-30-22-71
The ABB AF750B-30-22-71 is a 3-pole AC non-reversing contactor with 2 NO and 2 NC auxiliary contacts. It operates on 250-500 V DC and supports up to 700 HP at 575/600 V 3-phase. The coil draws 910 V·A pull-in and 12 V·A holding at the maximum rated control circuit voltage, 50 Hz. Ambient air temperature range is -25 to 50 °C close to the contactor fitted with a thermal overload relay (0.85 to 1.1 Uc), and -40 to 70 °C without a thermal overload relay (0.85 to 1.1 Uc). Dimensions are 210 mm wide, 242 mm deep, and 283 mm high; net weight is 13.6 kg. Manufacturer ID: 1SFL637063R7122.
- AF750F-30-11
The ABB AF750F-30-11 is a non-reversing AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V. Rated operational current AC-1 is 1050 A at 690 V and 40 °C, 875 A at 55 °C, and 720 A at 70 °C. Rated operational current AC-3 is 750 A at 415 V and 55 °C, and 650 A at 690 V and 55 °C. Rated control circuit voltage is 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. Mechanical durability is 3 million operating cycles. Dimensions are 210 mm width, 242 mm depth, and 283 mm height; net weight is 13.6 kg. Main circuit terminals are bars.
- AF80-22-00-11
The ABB AF80-22-00-11 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It uses screw terminals and measures 90 mm wide, 116 mm deep, and 125.5 mm high, weighing 1.49 kg. The main circuit is rated 1000 V, with a rated impulse withstand voltage of 8 kV and rated insulation voltage of 1000 V per IEC 60947-4-1 and 600 V per UL/CSA. AC-3 rated operational power is 37 kW at 380/400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. The control circuit operates at 24 to 60 V at 50/60 Hz or 20 to 60 V DC. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80-22-00-12
The ABB AF80-22-00-12 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 90 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.49 kg. The main circuit is rated 1000 V, with a rated impulse withstand voltage of 8 kV and an insulation voltage of 1000 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Rated operational current AC-3 is 80 A at 380/400 V and 60 degrees C, corresponding to 37 kW at 380/400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80-22-00-13
ABB AF80-22-00-13 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 90 mm wide, 116 mm deep, and 125.5 mm high, weighing 1.44 kg. The main circuit is rated 1000 V, with a rated impulse withstand voltage of 8 kV and insulation voltage of 1000 V per IEC 60947-4-1 and 600 V per UL/CSA. Rated operational current AC-3 is 80 A at 380/400 V and 60 °C, and rated operational power AC-3 is 37 kW at 380/400 V. Conventional free-air thermal current is 125 A per IEC 60947-4-1 for open contactors at 40 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80-22-00-14
The ABB AF80-22-00-14 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 90 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.44 kg. The main circuit is rated 1000 V, with a rated impulse withstand voltage of 8 kV and rated insulation voltage of 1000 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Conventional free-air thermal current is 125 A at 40 °C. AC-3 rated operational power is 37 kW at 380/400 V and 45 kW at 415/440/500/690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80-30-00-11
The ABB AF80-30-00-11 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.22 kg. The main circuit is rated 1000 V, with a control and main circuit frequency of 50/60 Hz. Conventional free-air thermal current is 130 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 220/230/240 V, 380/400 V, 415 V, and 440 V at 60 °C, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80-30-00-12
The ABB AF80-30-00-12 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a control circuit frequency of 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 130 A at 40 °C. AC-3 ratings include 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Corresponding AC-3 power ratings include 37 kW at 400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 70 mm wide, 116 mm deep, and 125.5 mm high, with a net weight of 1.22 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.