- AF16Z-30-01K-20
ABB AF16Z-30-01K-20 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It uses push-in spring terminals and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on 2 x M4 screws placed diagonally (not supplied). Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight is 0.315 kg. The control circuit is rated 12 to 20 V DC. Rated operational voltage is 690 V for main and auxiliary circuits at 50/60 Hz. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Ambient air temperature is -40 to 70 degrees C.
- AF16Z-30-01K-21
The ABB AF16Z-30-01K-21 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.315 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16Z-30-01K-22
The ABB AF16Z-30-01K-22 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It uses push-in spring terminals and measures 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.315 kg. Rated operational voltage is 690 V for main and auxiliary circuits at 50/60 Hz. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415, 440, 500, and 690 V. Rated control circuit voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC operation. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or with two M4 screws placed diagonally.
- AF16Z-30-01K-23
The ABB AF16Z-30-01K-23 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.315 kg. The main, auxiliary, and control circuits are rated 690 V, with a rated impulse withstand voltage of 6 kV and a rated insulation voltage of 690 V according to IEC 60947-4-1. Rated operational current AC-3 is 18 A at 380/400 V and 415 V at 60 °C, and rated operational power AC-3 is 7.5 kW at 380/400 V. The contactor uses push-in spring terminals and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16Z-30-01K-30
The ABB AF16Z-30-01K-30 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 97 mm deep, and 92.3 mm high, and weighs 0.435 kg. It is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. AC-3 ratings include 18 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 60 °C, 15 A at 500 V, and 10.5 A at 690 V. Corresponding AC-3 power ratings are 7.5 kW at 380/400 V, 9 kW at 415 V, 440 V, 500 V, and 690 V, and 4 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16Z-30-10-20
ABB AF16Z-30-10-20 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 35 A at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16Z-30-10-21
ABB AF16Z-30-10-21 is a 3-pole AC/DC operated contactor with 3 main contacts NO, 1 auxiliary contact NO, and no NC contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, weighing 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with rated frequency 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C open contactors, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 60 °C, 15 A at 500 V, and 10.5 A at 690 V. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16Z-30-10-22
ABB AF16Z-30-10-22 AC contactor, manufacturer ID 1SBL176001R2210. It has three normally open main contacts and one normally open auxiliary contact, with no normally closed contacts. Main and auxiliary circuits are rated 690 V, 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.31 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.