- AFS205-30-12-34
The ABB AFS205-30-12-34 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and a rated impulse withstand voltage of 8 kV. Conventional free-air thermal current is 350 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 205 A at 415 V and 60 °C, with rated operational power of 110 kW at 415 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high, weighing 2.4 kg.
- AFS26-30-22-11
The ABB AFS26-30-22-11 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It has two normally open and two normally closed auxiliary contacts. The contactor measures 45 mm wide, 119.5 mm deep, and 86 mm high, and weighs 0.36 kg. It is rated for auxiliary and main circuit operational voltages up to 690 V at 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V and 440 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 400 V and 15 kW at 440 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFS26-30-22-13
ABB AFS26-30-22-13 is a 3-pole AC contactor, manufacturer ID 1SBL237082R1322, with 3 N.O. main contacts and 2 N.O. plus 2 N.C. front-mounted auxiliary contacts. Control voltage is 100-250 V AC/DC; rated frequency is 50/60 Hz for auxiliary, control, and main circuits. Rated operational voltage is 690 V for both auxiliary and main circuits. AC-3 ratings include 26 A at 380/400 V and 60 °C, and rated operational power of 11 kW at 400 V and 15 kW at 440 V. Dimensions are 45 mm width, 119.5 mm depth/length, 86 mm height, and 0.36 kg net weight. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFS265-30-12-11
The ABB AFS265-30-12-11 is an AC contactor with three normally open main contacts and no normally closed main contacts. It has one normally open auxiliary contact and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 350 A at 1000 V and 40 °C, 300 A at 1000 V and 60 °C, and 240 A at 1000 V and 70 °C. AC-3 ratings include 265 A at 415 V and 60 °C. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 4 kg.
- AFS265-30-12-12
ABB AFS265-30-12-12 AC contactor, manufacturer ID 1SFL547082R1212. Three main contacts NO, no main contacts NC; auxiliary contacts: one NO and two NC. Main circuit rated operational voltage 1000 V at 50/60 Hz. Rated operational current AC-1: 350 A at 1000 V and 40 °C, 300 A at 60 °C, 240 A at 70 °C. Rated operational current AC-3: 265 A at 415 V and 60 °C. Rated control circuit voltage: 48 to 130 V at 50 Hz, 60 Hz, and DC operation. Coil operating limits per IEC 60947-4-1: 0.85 x Uc minimum to 1.1 x Uc maximum at temperatures up to 70 °C. Dimensions 140 mm width, 180 mm depth, 225 mm height; net weight 4 kg. Main terminals IP00, coil terminals IP20.
- AFS265-30-12-13
The ABB AFS265-30-12-13 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, both at 60 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 4 kg. Short-circuit protection uses gG type fuses rated 500 A.
- AFS265-30-12-14
The ABB AFS265-30-12-14 is an AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 350 A at 1000 V and 40 °C, and 400 A at 690 V and 40 °C. Rated operational current AC-3 is 265 A at 415 V and 60 °C. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 4 kg.
- AFS265-30-12-33
The ABB AFS265-30-12-33 is a 3-pole AC contactor with three normally open main contacts and one normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 4 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V at 60 °C, and rated operational power AC-3 is 132 kW at 415 V and 380/400 V. Short-circuit protection uses gG type fuses rated 500 A.