- NF40E-12 48-130V50/60HZ-DC
ABB NF40E-12 48-130V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 4-pole, Contacts configuration: NO x4, and Control voltage1: 48...130V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF40E-13
ABB NF40E-13 intermediate relay, manufacturer ID 1SBH137001R1340. It has four normally open auxiliary contacts and no normally closed contacts. The control circuit is rated 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.27 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF40E-13 100-250V50/60HZ-DC
ABB NF40E-13 100-250V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 4-pole, Contacts configuration: NO x4, and Control voltage1: 100...250V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF40E-14
The ABB NF40E-14 is an intermediate relay with four normally open auxiliary contacts and no normally closed contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with a conventional free-air thermal current of 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current is 6 A at 24/127 V and 2 A at 690 V in AC-15. The control circuit accepts 250 to 500 V at 50 Hz, 60 Hz, and DC. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 and conforms to IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, and CSA C22.2 No. 14-13.
- NF40E-14 250-500V50/60HZ-DC
ABB NF40E-14 250-500V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 4-pole, Contacts configuration: NO x4, and Control voltage1: 250...500V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF40EK-11
ABB NF40EK-11 intermediate relay, manufacturer ID 1SBH137005R1140. Four-pole contactor relay with 4 NO auxiliary contacts and 0 NC contacts, push-in spring terminals. Rated operational voltage 690 V for auxiliary and main circuits; rated frequency 50/60 Hz. Rated control circuit voltage 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Conventional free-air thermal current 16 A per IEC 60947-5-1 at 40 °C. Rated insulation voltage 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage 6 kV. Dimensions 45 mm wide, 77 mm deep, 92.3 mm high; net weight 0.285 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF40EK-12
ABB NF40EK-12 intermediate relay, manufacturer ID 1SBH137005R1240. It has 4 normally open auxiliary contacts and no normally closed contacts, with push-in spring terminals. Rated operational voltage is 690 V for both auxiliary and main circuits; rated frequency is 50/60 Hz for auxiliary and control circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC operation. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA; rated impulse withstand voltage is 6 kV. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight 0.285 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF40EK-13
ABB intermediate relay NF40EK-13, manufacturer ID 1SBH137005R1340. Four auxiliary contacts, all normally open, with push-in spring terminals. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA; rated impulse withstand voltage is 6 kV. Control circuit voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight 0.285 kg. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or two M4 screws placed diagonally. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.