- OT400U04DP
ABB isolating switch OT400U04DP, manufacturer ID 1SCA113428R1001. It is a front-operated, non-fusible switch with lug terminals, a black handle and shaft included, and lockable operation. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, rated operational voltage of the main circuit is 1000 V, rated impulse withstand voltage is 12 kV, and maximum operating voltage UL/CSA is 600 V. Conventional thermal current is 400 A fully enclosed; rated operational current AC-22A and AC-23A are 400 A at 380 to 415 V, 500 V, and 690 V. Rated short-circuit making capacity is 65 kA at 690 V, and rated short-time withstand current is 15 kA for 1 s. Standards: IEC 60947-3, UL 98, CSA C22.2 NO.4. Dimensions are 305 mm width, 185 mm height, 202.5 mm depth; net weight 7.5 kg.
- OT400U04P
ABB OT400U04P isolating switch, four-pole, front-operated, base mounting. Rated operational voltage 1000 V in the main circuit; rated insulation voltage 1000 V according to IEC/EN 60664-1; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated operational current AC-21A, AC-22A and AC-23A: 400 A at 380 to 415 V, 500 V and 690 V. Rated operational power AC-23A: 220 kW at 380 to 415 V, 280 kW at 500 V, 400 kW at 690 V. Rated short-circuit making capacity 65 kA at 690 V; rated short-time withstand current 15 kA for 1 s. Standards: IEC 60947-3, UL 98, CSA C22.2 NO.4. Front degree of protection IP00; pollution degree 3; mechanical durability 16000 operations; lug terminals, 25 mm wide; tightening torque 42.4 N·m according to IEC 60947-1.
- OT400U11
ABB OT400U11 isolating switch, 1SCA128952R1001. Rated operational voltage 1000 V main circuit; conventional thermal current 400 A fully enclosed; rated operational current AC-22A 400 A at 380–415 V, 500 V, and 690 V. Two poles. Rated insulation voltage 1000 V acc. to IEC/EN 60664-1; rated impulse withstand voltage 12 kV; rated short-time withstand current 15 kA for 1 s; rated short-circuit making capacity 65 kA at 690 V. Maximum operating voltage UL/CSA 600 V. Standards: IEC 60947-3, UL 98, CSA C22.2 NO.4. Lug terminals; tightening torque 42.4 N·m acc. IEC 60947-1. Front IP00; pollution degree 3. Mechanical durability 16000 operations. Power loss 10 W per pole at rated operating conditions. Dimensions 172 x 220 x 105 mm; 2.3 kg. Handle and shaft not included.
- OT400U12
The ABB OT400U12 is a 3-pole, front-operated non-fusible disconnect switch rated 400 A. It is base mounted with lug terminals and top-in/bottom-out or bottom-in/top-out line terminal positions. Conventional thermal current (Ithe) is 400 A fully enclosed. Rated impulse withstand voltage (Uimp) is 12 kV, with pollution degree 3 and front degree of protection IP00. Power loss is 10 W per pole at rated operating conditions. Mechanical durability is 16,000 operations. Dimensions are 226 mm wide, 220 mm high, and 105 mm deep; net weight is 3 kg (6.7 lb). Handle and shaft are not included. Manufacturer ID: 1SCA022754R6450.
- OT400U12-1000
The ABB OT400U12-1000 is a 3-pole isolating switch with a 200 A ampere rating. It is rated for a main circuit operational voltage of 1000 V and a maximum operating voltage of 1000 V per UL/CSA. Rated impulse withstand voltage (Uimp) is 12 kV, and rated short-time withstand current (Icw) is 15 kA for 1 s. Power loss is 25 W per pole at rated operating conditions. The switch measures 226 mm wide, 220 mm high, and 105 mm deep, with a net weight of 3.0 kg. It is manufactured to UL 98 and CSA C22.2 NO.4. The manufacturer identifier is 1SCA159826R1001.
- OT400U12C
ABB OT400U12C is a 3-pole, front-operated, non-fusible isolating switch. It is rated for a conventional free-air thermal current (Ith) of 400 A at 40 °C, with a rated insulation voltage (Ui) of 1000 V and a rated impulse withstand voltage (Uimp) of 12 kV. Power loss is 10 W per pole at rated operating conditions. The switch has a front degree of protection of IP20 and pollution degree 3. It uses base mounting, with line terminals configurable as top in - bottom out or bottom in - top out. Dimensions are 251 mm wide, 185 mm high, and 203 mm deep; net weight is 5.9 kg. Handle and shaft are not included. Manufacturer ID: 1SCA106497R1001.
- OT400U12CP
The ABB OT400U12CP is a 3-pole, front-operated switch-disconnector supplied as a base-mounting unit with handle and shaft included. Its conventional free-air thermal current (Ith) is 400 A at an ambient temperature of 40 °C, and its rated insulation voltage (Ui) is 1000 V. Rated impulse withstand voltage (Uimp) is 12 kV, with pollution degree 3. Power loss is 10 W per pole at rated operating conditions. Line terminals may be connected top in, bottom out, or bottom in, top out. Dimensions are 251 mm wide, 185 mm high, and 203 mm deep; net weight is 5.9 kg. Front degree of protection is IP20. The handle is black.
- OT400U12P
The ABB OT400U12P is a 3-pole, front-operated isolating switch supplied with handle and shaft. It is base-mounted with line terminals configurable as top in/bottom out or bottom in/top out. Rated conventional free-air thermal current is 400 A at 40 °C, and conventional thermal current for the fully enclosed condition is 400 A. Pollution degree is 3. The front degree of protection is IP00. Mechanical durability is 16000 operating cycles. Dimensions are 226 mm wide, 220 mm high, and 105 mm deep; net weight is 2.9 kg (6.3 lb). The handle is black and a lock is provided. Manufacturer ID: 1SCA022754R6960.