- OT1200U12
ABB OT1200U12 is a three-pole, front-operated isolating switch intended for base mounting. It has a rated insulation voltage of 1000 V according to IEC/EN 60664-1 and a rated impulse withstand voltage of 12 kV. Power loss is 48 W per pole at rated operating conditions. The switch provides front protection of IP00 and is rated for pollution degree 3. Mechanical durability is 6000 operations. Dimensions are 334.5 mm wide, 372 mm high, and 145.5 mm deep, with a net weight of 17.2 kg. Line terminals can be configured top in and bottom out, or bottom in and top out. A handle and shaft are not included. Manufacturer ID: 1SCA105659R1001.
- OT1200U12P
ABB OT1200U12P is a 3-pole, front-operated, non-fusible isolating switch. It is rated 1200 A and intended for base mounting. The switch has a black handle with shaft included and a lockable mechanism. Mechanical durability is 6000 operating cycles. Dimensions are 334.5 mm wide, 372 mm high, and 145.5 mm deep, with a net weight of 17 kg. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 12 kV. Power loss is 48 W per pole at rated operating conditions. Pollution degree is 3, and front degree of protection is IP00. Manufacturer ID: 1SCA022871R9270.
- OT1200U22
ABB OT1200U22 is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 414.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1200U30
ABB OT1200U30 is a 3-pole, front-operated isolating switch for base mounting. It has a rated operational current AC-22A of 1600 A at 380 to 415 V, 500 V, and 690 V. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 12 kV. Pollution degree is 3, with front degree of protection IP00. Power loss is 48 W per pole at rated operating conditions. Mechanical durability is 6000 operating cycles. Dimensions are 334.5 mm width, 372 mm height, and 145.5 mm depth, with a net weight of 17.2 kg. Handle and shaft are not included. Manufacturer ID: 1SCA106130R1001.
- OT1250E01
ABB OT1250E01 isolating switch, manufacturer ID 1SCA123136R1001. One-pole, front-operated switch disconnector for base mounting, with mechanism at the end of the switch on the left side. Rated insulation voltage 1000 V according to IEC/EN 60664-1; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 1250 A at 40 °C; conventional thermal current 1250 A fully enclosed. Rated operational current AC-21A, AC-22A, and AC-23A is 1250 A at 380 to 415 V, 500 V, and 690 V; AC-21A is also 1250 A at 1000 V. Rated operational power AC-23A is 710 kW at 400 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Standards: IEC 60947-3. Dimensions 174.5 mm wide, 306 mm high, 145.5 mm deep; 6.4 kg. Front protection IP00. Handle and shaft not included.
- OT1250E01P
The ABB OT1250E01P is a front-operated isolating switch with a black handle and shaft included. It is base mounting, has one pole, and the operating mechanism is at the end of the switch on the left side. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, with rated impulse withstand voltage 12 kV and pollution degree 3. Conventional free-air thermal current is 1250 A at 40 °C; conventional thermal current fully enclosed is 1250 A. Rated operational current AC-21A, AC-22A, and AC-23A is 1250 A at 380 to 415 V, 500 V, 690 V, and, for AC-21A, 1000 V. Rated operational power AC-23A is 710 kW at 400 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. It conforms to IEC 60947-3. Dimensions are 174.5 mm width, 306 mm height, and 167 mm depth; net weight 8.3 kg.
- OT1250E02
ABB OT1250E02 is a 2-pole isolating switch-disconnector, front-operated, base mounting. Manufacturer ID 1SCA106135R1001. Rated conventional free-air thermal current Ith 1250 A at 40 °C; conventional thermal current Ithe 1250 A fully enclosed. Power loss at rated operating conditions is 29 W per pole. Mechanical durability is 6000 operations. Line terminals can be configured top in/bottom out or bottom in/top out. Pollution degree 3. Front degree of protection IP00. Net dimensions: 254.5 mm width, 306 mm height, 145.5 mm depth; net weight 10.5 kg. Handle and shaft are not included. Lock type: no. Distance between phases: standard.
- OT1250E02K
The ABB OT1250E02K is a two-pole isolating switch-disconnector classified under ETIM EC000216. It is rated 1250 A conventional thermal current (fully enclosed) and 1000 V rated operational voltage. Rated operational currents are 1250 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated operational power AC-23A is 710 kW at 400 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated impulse withstand voltage is 12 kV; rated insulation voltage is 1000 V according to IEC/EN 60664-1. Short-circuit making capacity is 110 kA at 690 V, and short-time withstand current is 50 kA for 1 s. It has lug terminals, front IP00 protection, pollution degree 3, and 6000 mechanical operations. Dimensions are 254.5 mm width, 306 mm height, and 167 mm depth; net weight 1.4 kg. Handle and shaft are not included. Standards: IEC 60947-3.