- AF38Z-30-00K-20
ABB AF38Z-30-00K-20 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. The control circuit operates on DC 12 to 20 V. Main circuit ratings are 690 V and 50/60 Hz, with AC-3 operational current of 38 A at 415 V and 60 °C, and AC-3 operational power of 18.5 kW at 415 V. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C. Dimensions are 45 mm wide, 86 mm deep, and 92.3 mm high, weighing 0.36 kg. Push-in spring terminals accept main circuit conductors from 1 to 6 mm² flexible. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF38Z-30-00K-21
The ABB AF38Z-30-00K-21 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.36 kg. The main circuit is rated 690 V at 50/60 Hz, with AC-3 ratings of 38 A at 380/400 V and 18.5 kW at 380/400 V, both at 60 °C. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C. It complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Maximum electrical switching frequency is 1200 cycles per hour in AC-3.
- AF38Z-30-00K-22
The ABB AF38Z-30-00K-22 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.36 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 38 A at 380/400 V and 415 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, 22 kW at 440 V, 500 V, and 690 V, and 11 kW at 220/230/240 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF38Z-30-00K-23
The ABB AF38Z-30-00K-23 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.36 kg. The main circuit is rated 690 V, with a control circuit rated 50/60 Hz. Rated operational current AC-3 is 38 A at 380/400 V and 415 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, 22 kW at 440 V, 500 V, and 690 V, and 11 kW at 220/230/240 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF38Z-30-11-20
The ABB AF38Z-30-11-20 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 45 mm wide, 111.5 mm deep, and 86 mm high, and weighs 0.39 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 38 A at 415 V and 440 V, 33 A at 500 V, 24 A at 690 V, and 40 A at 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 400 V and 415 V, 22 kW at 440 V, 500 V, and 690 V, and 11 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF38Z-30-11-21
The ABB AF38Z-30-11-21 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 45 mm wide, 111.5 mm deep, and 86 mm high, and weighs 0.39 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 38 A at 415 V and 440 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 440 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF38Z-30-11-22
The ABB AF38Z-30-11-22 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 45 mm wide, 111.5 mm deep, and 86 mm high, and weighs 0.39 kg. The main and auxiliary circuits are rated 690 V, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 38 A at 415 V and 440 V, 33 A at 500 V, and 24 A at 690 V, at 60 °C. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 440 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF38Z-30-11-23
ABB AF38Z-30-11-23 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 45 mm wide, 111.5 mm deep, and 86 mm high, weighing 0.39 kg. Rated operational voltage is 690 V for main and auxiliary circuits, with 50/60 Hz rated frequency. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational power is 18.5 kW at 380/400 V and 415 V, 22 kW at 440 V, 500 V, and 690 V, and 11 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.