- AF16Z-30-22-21
The ABB AF16Z-30-22-21 is an AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.36 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16Z-30-22-22
ABB AF16Z-30-22-22 AC contactor, manufacturer ID 1SBL176001R2222. Three main contacts NO, zero NC; two auxiliary contacts NO and two NC. Screw terminals. Rated operational voltage 690 V for main and auxiliary circuits, 50/60 Hz. Rated control circuit voltage 48 to 130 V at 50 Hz, 48 to 130 V at 60 Hz, and 48 to 130 V DC. Rated operational current AC-3: 18 A at 415 V and 440 V, 15 A at 500 V, 10.5 A at 690 V, at 60 °C. Rated operational power AC-3: 7.5 kW at 400 V, 9 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions 45 mm wide, 110.5 mm deep, 86 mm high; 0.36 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16Z-30-22-23
The ABB AF16Z-30-22-23 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.36 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 380/400 V and 415 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16Z-40-00-20
The ABB AF16Z-40-00-20 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 35 A at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 60 °C, and rated operational power AC-3 is 7.5 kW at 400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF16Z-40-00-21
The ABB AF16Z-40-00-21 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V, 440 V, and 380/400 V at 60 °C, and 10.5 A at 690 V at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AF16Z-40-00-22
The ABB AF16Z-40-00-22 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a control circuit voltage of 48 to 130 V at 50 Hz, 60 Hz, or DC. Rated operational current AC-3 is 18 A at 415 V and 440 V at 60 °C, and rated operational power AC-3 is 7.5 kW at 400 V. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C with open contactors. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.31 kg. The contactor uses screw terminals and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF16Z-40-00-23
ABB AF16Z-40-00-23 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V at 50/60 Hz; the control circuit operates at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current Ith is 35 A at 40 °C for open contactors. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 4 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AF16Z-40-00-30
The ABB AF16Z-40-00-30 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 97 mm deep, and 86 mm high, and weighs 0.43 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 18 A at 415 V, 440 V, and 380/400 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.