- NF80EK-12
The ABB NF80EK-12 is an intermediate relay with eight normally open auxiliary contacts and no normally closed contacts. It measures 45 mm wide, 110.5 mm deep, and 92.3 mm high, and weighs 0.33 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, with a rated insulation voltage of 690 V to IEC 60947-5-1 and 600 V to UL/CSA. Conventional free-air thermal current is 16 A at 40 °C to IEC 60947-5-1. Rated control circuit voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC. It uses push-in spring terminals, mounts on TH35-15 or TH35-7.5 DIN rail to IEC 60715, and is rated IP20 on auxiliary and coil terminals. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF80EK-13
The ABB NF80EK-13 is an 8-pole contactor relay with eight normally open auxiliary contacts and no normally closed contacts. It uses push-in spring terminals and mounts on TH35-15 (35 x 15 mm) or TH35-7.5 (35 x 7.5 mm) DIN rail per IEC 60715, or on two M4 screws placed diagonally. The rated control circuit voltage is 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 16 A per IEC 60947-5-1 at 40 degrees C. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high, with a net weight of 0.33 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF80EK-14
ABB NF80EK-14 intermediate relay, manufacturer ID 1SBH137005R1480. It has 8 NO auxiliary contacts and 0 NC auxiliary contacts. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high, and 0.37 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NFAN02
ABB spare part NFAN02 is a fan assembly. The manufacturer's invoice description and ABB type designation both state "FAN ASSEMBLY no longer available." The product type is Spare_Parts and the frame size is Spare_Parts. It is a new part, not made to order, and not quote only. Order multiple is 1 EA. Product net weight is 0 kg and gross weight is 0 kg, with a gross volume of 0 in³. Core credit is 0.00. Stocked at Wickliffe, Ohio, United States. No further technical ratings, electrical parameters, or performance data are supplied.
- NFB22E-14
The ABB NFB22E-14 intermediate relay (manufacturer ID 1SBH137061R1422) has 2 NO and 2 NC auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards listed include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, IEC 60077-1, IEC 60077-2, and EN 50155.
- NFB22EK-14
ABB NFB22EK-14 intermediate relay, manufacturer ID 1SBH137063R1422. It has 2 NO and 2 NC auxiliary contacts and measures 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.325 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards listed include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, IEC 60077-1, IEC 60077-2, and EN 50155.
- NFB22ERT-14
ABB NFB22ERT-14 intermediate relay, manufacturer ID 1SBH137060R1422. It has 2 NO and 2 NC auxiliary contacts, a rated operational voltage of 690 V for the auxiliary circuit, and a conventional free-air thermal current of 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.32 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards listed include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, IEC 60077-1, IEC 60077-2, and EN 50155.
- NFB31E-14
ABB NFB31E-14 intermediate relay, manufacturer ID 1SBH137061R1431, measures 45 mm wide, 77 mm deep, and 86 mm high, weighing 0.31 kg. It has three normally open and one normally closed auxiliary contacts. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC operation. Rated impulse withstand voltage is 6 kV; rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, IEC 60077-1, IEC 60077-2, and EN 50155 (applicable parts). DIN-rail mounting is TH35-15 and TH35-7.5 according to IEC 60715.