Product Model
OT16M4
Material Number
1SCA022497R0730
Manufacturer
ABB
Product ID
83297

Get a Free Quote

Request pricing and availability for OT16M4.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
Front IP20
Product Net Weight
0.125 kg
Rated Conditional Short-Circuit Current (Inc)
(40 A fuse, ≤415V) 50 kA (25 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 750 V
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 3 kW (400 ... 415 V) 7.5 kW (500 V) 7.5 kW (690 V) 7.5 kW
See all specifications

Product Highlights

  1. Product Type: ABB OT16M4 four-pole front-operated switch-disconnector for base mounting
  2. Electrical Ratings: Rated operational current 16 A at 380 to 415 V AC-21A and AC-22A, 16 A at 500 V and 690 V AC-22A, and 16 A at 380 to 415 V and 500 V AC-23A, 10 A at 690 V AC-23A
  3. Switching Capacity: Rated operational power AC-23A 3 kW at 220 to 240 V, 7.5 kW at 400 to 415 V, 500 V, and 690 V, rated impulse withstand voltage 8 kV, rated insulation voltage 750 V, rated short-circuit making capacity 0.71 kA at 690 V, rated short-time withstand current 0.5 kA for 1 s, and rated conditional short-circuit current 50 kA with a 40 A fuse up to 415 V or a 25 A fuse at 690 V
  4. Terminations and Wiring: Screw terminals accept Cu cable cross-sections from 0.75 to 10 mm² with a tightening torque of 0.8 N·m, line terminals can be top-in bottom-out or bottom-in top-out, and the fourth pole is switched with simultaneous function on the right side
  5. Physical and Compliance Data: Front IP20 protection, pollution degree 3, dimensions 48 mm wide by 68 mm high by 73 mm deep, net weight 0.125 kg, mechanical durability 20,000 operations, power loss 0.3 W per pole at rated operating conditions, and standards IEC 60947-3, UL 508, and CSA C22.2 No. 14
OT16M4

Product Information

Technical Specifications

Specifications for OT16M4

ParameterValue
Degree of ProtectionFront IP20
Environmental Information1SCC301262D0201
Pollution Degree3
Product Net Width48 mm
Product Net Height68 mm
Product Net Depth / Length73 mm
Product Net Weight0.125 kg
Cable Cross-SectionCu 0.75 ... 10 mm²
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 25 A
Conventional Thermal Current (Ithe)Fully Enclosed 25 A
Degree of ProtectionFront IP20
Distance Between PhasesStandard
Fourth Pole PositionRight Side
Fourth Pole TypeSwitched - Simultaneous Function
Handle TypeHandle and shaft not included
Lock TypeNo
Mechanical Durability20000
Mounting TypeBase mounting
Number of Poles4P
Operating ModeFront operated
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out Bottom In - Top Out
Power Lossat Rated Operating Conditions per Pole 0.3 W
Rated Conditional Short-Circuit Current (Inc)(40 A fuse, ≤415V) 50 kA (25 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)(380 ... 415 V) 16 A
ParameterValue
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 16 A (500 V) 16 A (690 V) 16 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 16 A (500 V) 16 A (690 V) 10 A
Rated Operational Power AC-23A (Pe)(220 ... 240 V) 3 kW (400 ... 415 V) 7.5 kW (500 V) 7.5 kW (690 V) 7.5 kW
Rated Operational VoltageMain Circuit 750 V
Rated Short-Circuit Making Capacity (Icm)(690 V) 0.71 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 0.5 kA
Special FunctionsNo
StandardsIEC 60947-3UL 508CSA C22.2 No. 14
Switches Operating MechanismMechanism on Top of the Switch
Terminal TypeScrew Terminals
Tightening Torqueacc. IEC 60947-1 0.8 N·m
Horsepower Rating UL/CSA(110 ... 120 V AC) Single Phase 1 Hp (240 V AC) Single Phase 2 Hp (440 ... 480 V AC) Single Phase 5 Hp (550 ... 600 V AC) Single Phase 7.5 Hp (220 ... 240 V AC) Three Phase 5 Hp (440 ... 480 V AC) Three Phase 10 Hp (550 ... 600 V AC) Three Phase 10 Hp
Tightening Torqueacc. IEC 60947-1 0.8 N·m
Object Classification CodeQ
ETIM 8EC000216 - Switch disconnector
ETIM 9EC000216 - Switch disconnector (low voltage)
eClassV11.1 : 27371403
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Sweden)3171077
Manufacturer ID1SCA022497R0730

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.