- AF460B-30-22-68
ABB AF460B-30-22-68 is a 3-pole AC contactor. Manufacturer ID: 1SFL597063R6822. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg. Coil consumption is 12 V·A holding and 900 V·A pull-in at maximum rated control circuit voltage at 50 Hz. Ambient air temperature ranges are -25 to 50 °C close to the contactor fitted with a thermal overload relay at 0.85 to 1.1 Uc, and -40 to 70 °C close to the contactor without a thermal overload relay at 0.85 to 1.1 Uc. ETIM 9 classification is EC000066, power contactor, AC switching.
- AF460B-30-22-69
The ABB AF460B-30-22-69 is a 3-pole AC contactor for motor control. It measures 186 mm wide, 216 mm deep, and 278 mm high, and weighs 10.6 kg. The coil consumption is 12 V·A holding and 1150 V·A pull-in at the maximum rated control circuit voltage at 50 Hz. Ambient air temperature ranges are -25 to 50 °C close to the contactor fitted with a thermal overload relay (0.85 to 1.1 Uc) and -40 to 70 °C close to the contactor without a thermal overload relay (0.85 to 1.1 Uc). The manufacturer ID is 1SFL597063R6922. ETIM classifications list it as EC000066 power contactor, AC switching.
- AF460B-30-22-70
The ABB AF460B-30-22-70 is a three-phase AC contactor, identified by manufacturer ID 1SFL597063R7022. It measures 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg. The control coil operates over a 100–250 V AC/DC range and includes built-in surge protection. Coil consumption is 12 V·A holding and 895 V·A pull-in at the maximum rated control circuit voltage at 50 Hz. Ambient air temperature limits are -25 to 50 °C when mounted close to a contactor fitted with a thermal overload relay (0.85–1.1 Uc), and -40 to 70 °C without a thermal overload relay (0.85–1.1 Uc). Mechanical durability is 5 million cycles. ETIM classification is EC000066.
- AF460B-30-22-71
ABB AF460B-30-22-71 is a 3-pole AC contactor, manufacturer ID 1SFL597063R7122, classified as EC000066 power contactor for AC switching. It measures 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg. Coil consumption is 12 V·A holding and 885 V·A pull-in at the maximum rated control circuit voltage at 50 Hz. Ambient air temperature ranges are -25 to 50 °C close to the contactor fitted with a thermal overload relay at 0.85 to 1.1 Uc, and -40 to 70 °C without a thermal overload relay at 0.85 to 1.1 Uc. Object classification code Q; eClass V11.0 27371003; UNSPSC 39121529.
- AF460F-30-11
ABB AF460F-30-11 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 186 mm wide, 216 mm deep, and 278 mm high, and weighs 10.6 kg. The main circuit is rated 1000 V, with AC-1 ratings of 700 A at 40 °C and 480 A at 70 °C at 690 V. AC-3 ratings include 460 A at 415 V and 400 A at 690 V. Rated control circuit voltage is 250 to 500 V at 50 Hz. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 Group C, and 600 V per UL/CSA. Mechanical durability is 3 million operations. Main circuit terminals are bars.
- AF460W-30-01 100-250V
The ABB AF460W-30-01 100-250V is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. Its control circuit operates at 100 to 250 V AC (50/60 Hz) or 100 to 250 V DC. Rated operational voltage for the main circuit is 1000 V, with AC-1 ratings of 700 A at 40 °C and 600 A at 60 °C (1000 V). AC-3 ratings include 460 A at 415 V and 55 °C, and 400 A at 690 V and 55 °C. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg.
- AF460W-30-11
The ABB AF460W-30-11 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 1000 V, with AC-1 ratings of 700 A at 40 °C and 480 A at 70 °C at both 690 V and 1000 V. AC-3 ratings include 460 A at 415 V, 440 V, 500 V, and 380/400 V, and 400 A at 690 V, all at 55 °C. AC-3 power ratings include 250 kW at 415 V and 440 V, 315 kW at 500 V, and 355 kW at 690 V. The control circuit accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Mechanical durability is 3 million operations, with maximum electrical switching frequency of 300 cycles per hour. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg.
- AF460W-30-22
ABB AF460W-30-22 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. The main circuit is rated 1000 V. Rated operational current AC-1 is 700 A at 1000 V and 40 °C, 600 A at 1000 V and 60 °C, and 480 A at 1000 V and 70 °C. Rated operational current AC-3 is 460 A at 415 V and 55 °C, 400 A at 690 V and 55 °C, and 200 A at 1000 V and 55 °C. Rated operational power AC-3 is 250 kW at 415 V, 315 kW at 500 V, and 355 kW at 690 V. Control circuit voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; weight 10.6 kg. Main terminals are bars.