- OT4000E12
The ABB OT4000E12 is a 3-pole isolating switch with base mounting and front operation. The mechanism is located between the poles, and line terminals may be connected top in/bottom out or bottom in/top out. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, with rated impulse withstand voltage 8 kV. Conventional free-air thermal current is 3800 A at 40 °C. Rated operational current is 3800 A at 380 to 415 V in AC-21B and AC-22B. Rated short-time withstand current is 80 kA for 1 s; rated short-circuit making capacity is 176 kA at 690 V. Mechanical durability is 5000 operations. Lug terminals accept 50 to 75 N·m per IEC 60947-1. Dimensions are 514 mm wide, 410 mm high, and 146 mm deep; net weight is 36.2 kg. Front protection is IP00; pollution degree 3. Standards: IEC 60947-3. Handle and shaft are not included.
- OT4000E12P
ABB OT4000E12P isolating switch, manufacturer ID 1SCA124852R1001. Three-pole, front-operated switch-disconnector for base mounting, with mechanism between the poles and lug terminals. Rated insulation voltage 1000 V according to IEC/EN 60664-1; rated operational voltage 1000 V main circuit; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 3800 A at 40 °C. Rated operational current AC-21B and AC-22B: 3800 A at 380 to 415 V. Rated short-circuit making capacity 176 kA at 690 V; rated short-time withstand current 80 kA for 1 s. Mechanical durability 5000 cycles. Front degree of protection IP00, pollution degree 3. Dimensions 514 mm wide, 410 mm high, 146 mm deep; net weight 37 kg. Standards: IEC 60947-3.
- OT4000E13
The ABB OT4000E13 is a four-pole isolating switch with a front-operated mechanism mounted between the poles. It is rated 1000 V in the main circuit, with a rated insulation voltage of 1000 V according to IEC/EN 60664-1 and a rated impulse withstand voltage of 8 kV. Conventional free-air thermal current is 3800 A at 40 °C. Rated operational current is 3800 A at 380 to 415 V in AC-21B and AC-22B. Rated short-time withstand current is 80 kA for 1 s, and rated short-circuit making capacity is 176 kA at 690 V. It is base mounting, with front IP00 protection, lug terminals, and a tightening torque of 50 to 75 N·m according to IEC 60947-1. Mechanical durability is 5000 cycles. The handle and shaft are not included.
- OT4000E13P
ABB OT4000E13P is a four-pole, front-operated isolating switch with base mounting and lug terminals. It is rated 1000 V in the main circuit, with a rated insulation voltage of 1000 V according to IEC/EN 60664-1, a rated impulse withstand voltage of 8 kV, and pollution degree 3. Conventional free-air thermal current is 3800 A at 40 °C. Rated operational current is 3800 A at 380 to 415 V for AC-21B and AC-22B. Rated short-time withstand current is 80 kA for 1 s; rated short-circuit making capacity is 176 kA at 690 V. Mechanical durability is 5000 operating cycles, power loss is 130 W per pole at rated operating conditions, and tightening torque is 50 to 75 N·m according to IEC 60947-1. Standards: IEC 60947-3. Front degree of protection: IP00. Dimensions: 654 mm width, 410 mm height, 146 mm depth; net weight 48.3 kg.
- OT4000E21
The ABB OT4000E21 is a three-pole, front-operated isolating switch intended for base mounting. It is rated 1000 V in the main circuit, with a rated insulation voltage of 1000 V according to IEC/EN 60664-1 and a rated impulse withstand voltage of 8 kV. Conventional free-air thermal current is 3800 A at 40 °C. Rated operational current is 3800 A at 380 to 415 V for AC-21B and AC-22B. Rated short-time withstand current is 80 kA for 1 s, and rated short-circuit making capacity is 176 kA at 690 V. It conforms to IEC 60947-3. Dimensions are 514 mm wide, 410 mm high, and 146 mm deep, weighing 36.2 kg. Front degree of protection is IP00. Handle and shaft are not included.
- OT4000E22
ABB OT4000E22 is a four-pole isolating switch with front operation and base mounting. The fourth pole is on the right side and switched with a simultaneous function. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, rated operational voltage of the main circuit is 1000 V, and rated impulse withstand voltage is 8 kV. Conventional free-air thermal current Ith is 3800 A at 40 °C. Rated operational current is 3800 A at 380 to 415 V for AC-21B and AC-22B. Rated short-time withstand current Icw is 80 kA for 1 s; rated short-circuit making capacity Icm is 176 kA at 690 V. Standards: IEC 60947-3. Dimensions are 654 mm wide, 410 mm high, and 146 mm deep; net weight 47.5 kg. Front protection is IP00; handle and shaft are not included.
- OT4000E22P
The ABB OT4000E22P is a four-pole front-operated switch-disconnector for base mounting. It is rated 1000 V in the main circuit, with rated insulation voltage 1000 V according to IEC/EN 60664-1 and rated impulse withstand voltage 8 kV. Conventional free-air thermal current is 3800 A at 40 °C. Rated operational current is 3800 A at 380 to 415 V for AC-21B and AC-22B. Rated short-circuit making capacity is 176 kA at 690 V, and rated short-time withstand current is 80 kA for 1 s. The fourth pole is switched with simultaneous function and positioned on the right side. Terminals are lug type, tightened to 50 to 75 N·m according to IEC 60947-1. Mechanical durability is 5000 operations. Dimensions are 654 mm wide, 410 mm high, and 146 mm deep; net weight is 48.3 kg. Standards: IEC 60947-3.
- OT400DAUA3AZ
The ABB OT400DAUA3AZ is a 3-pole, front-operated non-fusible disconnect switch supplied in a steel sheet enclosure. Its conventional thermal current (Ithe) is 400 A fully enclosed, and the rated conditional short-circuit current (Inc) is 61.5 kA. The enclosure provides IP65 protection according to IEC 60529, with pollution degree 3. Dimensions are 400 mm wide, 800 mm high, and 230 mm deep; net weight is 28 kg. Cable entry is down/down, with blank/open cable outlets per side. Main circuit connections use screw clamps with 10 mm hole diameter and a PE terminal for 4 pieces, 25 to 120 mm². The pistol handle is red/yellow. Mounted auxiliary contacts are 2 NO and 1 NC, with a maximum of 2 NO and 2 NC. Power loss is 10 W per pole at rated operating conditions.