- OT40F3/BSP50
ABB isolating switch, display model OT40F3/BSP50, manufacturer ID 1SCA135426R1001. Three-pole, front-operated, non-fusible disconnect switch for DIN rail mounting with protected clamp terminals. Rated conventional thermal current (Ithe) 40 A fully enclosed. Rated operational current AC-22A: 40 A at 380 to 415 V, 40 A at 500 V, 40 A at 690 V. Rated operational current AC-23A: 23 A at 380 to 415 V, 23 A at 500 V, 12 A at 690 V. Rated insulation voltage (Ui) 750 V according to IEC/EN 60664-1; rated impulse withstand voltage (Uimp) 8 kV. Pollution degree 3, front degree of protection IP20. Cable cross-section Cu 0.75 to 10 mm². Mechanical durability 20000 operations. Power loss 1.6 W per pole at rated operating conditions. Dimensions 35 mm width, 68 mm height, 56 mm depth. Knob handle and shaft not included.
- OT40F3C
ABB OT40F3C is a 3-pole isolating switch for base mounting, front operated, with a black handle. The handle and shaft are not included. It is rated 40 A conventional free-air thermal current (Ith) at 40 °C and 40 A conventional thermal current (Ithe) fully enclosed. Rated impulse withstand voltage (Uimp) is 8 kV; power loss is 1.6 W per pole at rated operating conditions. Cable cross-section accepts 0.75 to 10 mm². Front degree of protection is IP20, pollution degree 3. Line terminals may be connected top in - bottom out or bottom in - top out. Dimensions are 70 mm width, 68 mm height, and 68 mm depth; net weight is 0.25 kg. Manufacturer ID 1SCA104913R1001.
- OT40F3U
The ABB OT40F3U is a 3-pole isolating switch with front operation and base mounting. It is rated 40 A, with conventional free-air thermal current Ith of 40 A at 40 °C and conventional thermal current Ithe of 40 A fully enclosed. Rated insulation voltage is 750 V according to IEC/EN 60664-1, rated impulse withstand voltage is 8 kV, and rated operational voltage for the main circuit is 750 V. Rated operational current AC-23A is 23 A at 380 to 415 V and 500 V, and 12 A at 690 V. Power loss is 1.6 W per pole at rated operating conditions. Dimensions are 35 mm wide, 68 mm high, and 56 mm deep; net weight is 0.095 kg. Cable cross-section accepts Cu 0.75 to 10 mm². Standards: IEC 60947-3, UL 508, CSA C22.2 No. 14.
- OT40F3U/B50
The ABB OT40F3U/B50 is a front-operated, 3-pole isolating switch rated 40 A. It is a non-fusible switch-disconnector with screw terminals accepting Cu cable cross-sections of 0.75 to 10 mm². The conventional thermal current (Ithe) is 40 A fully enclosed, and rated operational current AC-22A is 40 A at 380 to 415 V, 500 V, and 690 V. Rated insulation voltage is 750 V according to IEC/EN 60664-1, with a rated impulse withstand voltage of 8 kV. The switch measures 35 mm wide, 68 mm high, and 56 mm deep, weighs 4.8 kg, and has front IP20 protection. It is rated for 20000 mechanical operations and conforms to IEC 60947-3, UL 508, and CSA C22.2 No. 14. The knob handle and shaft are not included.
- OT40F4C
The ABB OT40F4C is a 4-pole front-operated isolating switch for base mounting. Its conventional free-air thermal current (Ith) is 40 A at 40 °C, and its conventional thermal current for a fully enclosed installation (Ithe) is 40 A. Cable cross-section range is 0.75 to 10 mm². The fourth pole is on the right side and is switched with simultaneous function. Line terminals can be configured top in/bottom out or bottom in/top out. The front degree of protection is IP20, with pollution degree 3. Dimensions are 96 mm width, 68 mm height, and 68 mm depth; net weight is 0.27 kg. The handle and shaft are not included. Manufacturer ID: 1SCA104934R1001.
- OT40F4N1
ABB OT40F4N1 is a four-pole isolating switch with screw terminals. Conventional thermal current (Ithe) is 40 A fully enclosed, and rated operational current AC-22A is 40 A at 380 to 415 V, 500 V, and 690 V. Rated operational current AC-23A is 23 A at 380 to 415 V and 500 V, and 12 A at 690 V. Rated insulation voltage (Ui) is 750 V according to IEC/EN 60664-1; rated impulse withstand voltage (Uimp) is 8 kV. Rated operational voltage for the main circuit is 750 V. Standards: IEC 60947-3, UL 508, CSA C22.2 No. 14. Maximum operating voltage UL/CSA is 600 V. Dimensions are 48 mm wide, 68 mm high, and 56 mm deep; net weight is 0.125 kg. Front degree of protection is IP20. Cable cross-section is Cu 0.75 to 10 mm². Handle type: knob handle and shaft not included. Lock type: no.
- OT40F4N2
ABB OT40F4N2 is a front-operated, 4-pole load-break switch disconnector with screw terminals and protected clamp terminals. It is base-mounted with the operating mechanism on top of the switch; the fourth pole is on the right side and switched with a simultaneous function. The handle and shaft are not included. Rated insulation voltage is 750 V according to IEC/EN 60664-1, rated impulse withstand voltage is 8 kV, and conventional free-air thermal current Ith is 40 A at 40 °C. Rated operational current AC-23A is 23 A at 380–415 V and 500 V, and 12 A at 690 V. Standards: IEC 60947-3, UL 508, CSA C22.2 No. 14. Dimensions: 48 mm wide, 68 mm high, 56 mm deep; net weight 0.125 kg.
- OT40F4N2/B50
The ABB OT40F4N2/B50 is a 4-pole isolating switch with screw terminals and a front IP20 degree of protection. Conventional thermal current (Ithe) is 40 A fully enclosed; rated operational current AC-22A is 40 A at 380 to 415 V, 500 V, and 690 V. AC-23A ratings are 23 A at 380 to 415 V, 23 A at 500 V, and 12 A at 690 V. Rated insulation voltage is 750 V according to IEC/EN 60664-1, rated impulse withstand voltage is 8 kV, and rated operational voltage for the main circuit is 750 V. Cable cross-section accepts Cu 0.75 to 10 mm². Dimensions are 48 mm wide, 68 mm high, and 56 mm deep. Standards: IEC 60947-3, UL 508, CSA C22.2 No. 14.