- OT160EV12P
ABB OT160EV12P is a 3-pole isolating switch supplied with handle and shaft, front operated and base mounted. Rated conventional thermal current is 160 A fully enclosed and 200 A free-air at 40 °C. Dimensions are 150.5 mm width, 150 mm height, and 82.5 mm depth, with a net weight of 1.5 kg. Front degree of protection is IP00 and pollution degree is 3. Line terminals can be configured top in/bottom out or bottom in/top out. Mechanical durability is 20000 operations. The handle is black and a lock is provided. Manufacturer ID 1SCA120529R1001.
- OT160EV12WP
ABB OT160EV12WP is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301265D0201, Pollution Degree: 3, and Product Net Width: 174.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT160EV22
ABB OT160EV22 is a 4-pole front-operated switch-disconnector with base mounting. The fourth pole is on the right side and is switched with simultaneous function. Conventional free-air thermal current Ith is 200 A at 40 °C; conventional thermal current Ithe is 160 A fully enclosed. Pollution degree is 3, and front degree of protection is IP00. Dimensions are 150 mm width, 180.5 mm height, and 82.5 mm depth; net weight is 1.5 kg. Mechanical durability is 20000 operations. The handle and shaft are not included, and no lock is provided. Manufacturer ID 1SCA120535R1001.
- OT160EV22K
The ABB OT160EV22K is a four-pole, front-operated isolating switch with base mounting and a direct-mounted black pistol-type handle. It is rated 160 A fully enclosed (Ithe) and 200 A conventional free-air thermal current at 40 °C. Rated insulation voltage is 1000 V per IEC/EN 60664-1, rated impulse withstand voltage is 12 kV, and rated operational voltage for the main circuit is 1000 V. It conforms to IEC 60947-3. Terminal type is lug terminals with tightening torque of 15 to 22 N·m per IEC 60947-1. Dimensions are 180.5 mm wide, 150 mm high, and 107 mm deep, with a net weight of 1.8 kg. The fourth pole is switched, simultaneous function, mounted on the right side.
- OT160EV22P
ABB OT160EV22P is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301265D0201, Pollution Degree: 3, and Product Net Width: 185.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT160EV22WP
ABB OT160EV22WP is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301265D0201, Pollution Degree: 3, and Product Net Width: 217.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT160EV33
ABB OT160EV33 isolating switch, six-pole (6P), front-operated, base mounting. Rated insulation voltage 1000 V according to IEC/EN 60664-1; rated impulse withstand voltage 12 kV; pollution degree 3. Conventional free-air thermal current 200 A at 40 °C; conventional thermal current 160 A fully enclosed. Rated operational current: AC-21A 200 A at 380 to 415 V, 500 V, and 690 V; AC-22A 200 A at 380 to 415 V and 500 V, 160 A at 690 V; AC-23A 160 A at 380 to 415 V, 500 V, and 690 V; DC-21B 160 A at 1000 V. Rated short-circuit making capacity 30 kA at 690 V; short-time withstand current 8 kA for 1 s. Power loss 3.2 W per pole at rated operating conditions. Standards: IEC 60947-3. Dimensions 150 mm wide, 250.5 mm high, 82.5 mm deep; net weight 2.4 kg. Front protection IP00. Handle and shaft not included.
- OT160EV33P
The ABB OT160EV33P is a 6-pole, front-operated switch-disconnector for base mounting, with handle and shaft included (black handle). It is rated 160 A fully enclosed (Ithe) and 200 A conventional free-air thermal current (Ith) at 40 °C. Rated insulation voltage is 1000 V per IEC/EN 60664-1; rated impulse withstand voltage is 12 kV. Rated operational current AC-21A is 200 A at 380 to 415 V, 500 V, and 690 V; DC-21B is 160 A at 1000 V. Rated short-circuit making capacity is 30 kA at 690 V; short-time withstand current is 8 kA for 1 s. Power loss is 3.2 W per pole at rated operating conditions. Lug terminals; tightening torque 15 to 22 N·m per IEC 60947-1. Front protection IP00; pollution degree 3. Dimensions 255.5 x 150 x 82.5 mm; net weight 2.63 kg. Standard: IEC 60947-3.