- DS201 C32 AC100
ABB DS201 C32 AC100 is a 1P+N leakage protection circuit breaker (RCBO) with a rated current of 32 A and rated residual current of 100 mA, Type AC. Tripping characteristic C. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV; dielectric test voltage 2 kV. Rated short-circuit capacity 6 kA; rated ultimate short-circuit breaking capacity 10 kA; rated service short-circuit breaking capacity 7.5 kA. Rated frequency 50 to 60 Hz. Complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. Two poles, one protected pole, two modular spacings, DIN-rail mounting. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Dimensions 35 x 85 x 69 mm, 200 g. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20/IP40.
- DS201 C32 AC30
ABB DS201 C32 AC30 leakage protection circuit breaker, 1P+N, 32 A rated current, 30 mA rated residual current, Type AC residual current, C tripping characteristic. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV. Rated short-circuit capacity 6 kA; rated ultimate short-circuit breaking capacity 10 kA; rated service short-circuit breaking capacity 7.5 kA. Two poles, one protected pole, two modular spacings, DIN-rail mounting. Screw terminals accept stranded conductors 0.75 to 25 mm²; tightening torque 2.8 N·m. Electrical endurance 10000 cycles; mechanical endurance 20000 cycles. Ambient air temperature range -25 to 55 °C. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1.
- DS201 C32 AC300
ABB DS201 C32 AC300 is a DIN-rail mounted leakage protection circuit breaker (RCBO) with a rated current of 32 A and rated residual current of 300 mA, Type AC. It has a C tripping characteristic, two poles with one protected pole, and a rated operational voltage of 240 V AC according to IEC 60898-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Screw terminals accept conductors from 0.75 to 25 mm², tightening torque 2.8 N·m. Dimensions are 35 mm width, 85 mm height, 69 mm depth; weight 200 g. Operating ambient air temperature is -25 to 55 °C.
- DS201 C32 APR100
ABB DS201 C32 APR100 is a 1P+N residual current circuit breaker (RCBO) with two poles, one protected pole, and a C tripping characteristic. It is rated 32 A, 100 mA Type A residual current, 240 V AC according to IEC 60898-1, and 50 to 60 Hz. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA; rated service short-circuit breaking capacity (Ics) is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Maximum surge current is 3 kA. Contact position is indicated red ON / green OFF, with a blue flag on the toggle for fault indication. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Operating ambient air temperature is -25 to 55 °C. Screw terminals accept 0.75 to 25 mm²; tightening torque is 2.8 N·m.
- DS201 C32 APR30
ABB DS201 C32 APR30 is a 1P+N residual current circuit breaker (RCBO) for single-phase circuits. Rated current is 32 A with a C tripping characteristic and 30 mA Type A residual current. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) is 10 kA, and rated service short-circuit breaking capacity (Ics) is 7.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. Terminal tightening torque is 2.8 N·m. Operating ambient air temperature range is -25 to 55 °C.
- DS201 C32 APR300
The ABB DS201 C32 APR300 is a 1P+N residual current circuit breaker with overcurrent protection, identified by manufacturer ID 2CSR255480R3324. It has a rated current of 32 A, a rated residual current of 300 mA, Type A residual current, and C tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity is 10 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device occupies two modular spacings on DIN rail, measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g. Operating ambient air temperature is -25 to 55 °C.
- DS201 C32 G30
The ABB DS201 C32 G30 is a 1P+N leakage protection circuit breaker (RCBO) with a rated current of 32 A and rated residual current of 30 mA. It has a C tripping characteristic and Type A/G residual current. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. Screw terminals accept 0.75 to 25 mm² conductors. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20/IP40.
- DS201 C35 A30 UL
The ABB DS201 C35 A30 UL is a leakage protection circuit breaker with a C tripping characteristic and Type A residual current detection. It has a rated current of 35 A and a rated residual current of 30 mA. Rated operational voltage is 240 V according to IEC 60898-1, with a rated insulation voltage of 500 V per IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. It provides one protected pole in a two-pole configuration, mounts on DIN rail, and measures 35 mm wide, 85 mm high, and 69 mm deep. Standards cited include IEC 61009-1, IEC 61009-2-1, UL 1053, UL 1077, and CSA C22.2 No. 235. Ambient air temperature range is -25 to 55 degrees C.