- ESB20-20N-07
The ABB ESB20-20N-07 is a two-pole building contactor with two normally open main contacts and no auxiliary contacts. It is rated 20 A at AC-1 and AC-7a, and 9 A at AC-3 and AC-7b, both single phase at 230 V, with corresponding powers of 4.6 kW and 1.3 kW. Main circuit rated operational voltage is 220 V DC or 250 V AC; rated insulation voltage is 400 V and rated impulse withstand voltage is 6 kV. It measures 18 mm wide, 85 mm high, and 65 mm deep, weighs 0.14 kg, and carries IP20 protection. Electrical durability is 150000 cycles and mechanical durability 1000000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, and IEC 60335-2-40 A2L.
- ESB20-20N-14
ABB ESB20-20N-14 building contactor, manufacturer ID 1SBE121111R1420. Two-pole (2 NO main contacts, no auxiliary contacts), 1 modular spacing wide, dimensions 18 mm W x 85 mm H x 65 mm D, net weight 0.14 kg. Rated operational voltage: main circuit 220 V DC and 250 V AC. Rated control circuit voltage 12 V. Rated operational current AC-1 (NO) 20 A; AC-3 (230 V, single phase, NO) 9 A; AC-7a (NO) 20 A; AC-7b (230 V, single phase, NO) 9 A. Rated operational power AC-1 (230 V, single phase, NO) 4.6 kW; AC-3 (230 V, single phase, NO) 1.3 kW. Rated impulse withstand voltage 6 kV, rated insulation voltage 400 V, pollution degree 3, IP20. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, IEC 60335-2-40 A2L.
- ESB25-04N-01
ABB building contactor ESB25-04N-01, manufacturer ID 1SAE231111M0104. Four-pole installation contactor with four NC main contacts and no auxiliary contacts. Rated operational voltage: main circuit 220 V DC and 400 V AC; rated control circuit voltage 24 V. Rated operational current AC-1 (NC) 25 A; AC-3 (NC) 6 A at 230 V single phase. Rated operational power AC-1: 5.8 kW at 230 V single phase and 17.3 kW at 400 V three phase. Rated insulation voltage 500 V; rated impulse withstand voltage 6 kV. Dimensions 36 mm wide, 85 mm high, 65 mm deep; 0.245 kg. DIN rail mounting, IP20, pollution degree 3. Ambient air temperature: operation -25 to +55 °C, storage -40 to +80 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1.
- ESB25-04N-02
ABB ESB25-04N-02 building contactor, 4-pole (4 NC main contacts, no auxiliary contacts), 2 modular spacings wide. Rated operational current AC-1 (NC) 25 A and AC-7a (NC) 25 A; AC-3 (NC) 6 A at 230 V single phase. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage (Uc) 42 V. Rated insulation voltage 500 V; rated impulse withstand voltage 6 kV. Dimensions 36 mm wide, 85 mm high, 65 mm deep; net weight 0.245 kg. Degree of protection IP20. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L. Ambient operating temperature -25 to +55 °C.
- ESB25-04N-03
The ABB ESB25-04N-03 is a four-pole building contactor with four normally closed main contacts and no auxiliary contacts. It measures 36 mm wide, 85 mm high, and 65 mm deep, and weighs 0.245 kg. The main circuit is rated 220 V DC and 400 V AC; the control circuit is rated 48 V. Rated operational current is 25 A AC-1 (NC), 6 A AC-3 at 230 V single phase (NC), 25 A AC-7a (NC), and 6 A AC-7b at 400 V three phase (NC). Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Degree of protection is IP20, pollution degree 3, and maximum operating altitude is 2000 m. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- ESB25-04N-06
ABB building contactor ESB25-04N-06, four-pole (4 NC main contacts, no auxiliary contacts), 2 modular spacings wide. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage Uc 230 to 240 V. Rated operational current AC-1 (NC) 25 A; AC-3 (NC) 6 A at 230 V single phase; AC-7a (NC) 25 A; AC-7b (NC) 6 A at 400 V three phase. Rated impulse withstand voltage 6 kV, rated insulation voltage 500 V, pollution degree 3, IP20. Dimensions 36 mm wide, 85 mm high, 65 mm deep; net weight 0.235 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB25-04N-07
ABB building contactor ESB25-04N-07, manufacturer ID 1SAE231111M0704. Four-pole installation contactor with four main contacts, all normally closed, and no auxiliary contacts. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 400 to 415 V. Rated operational current AC-1 (NC) 25 A; AC-3 (NC) 6 A at 230 V single phase. Rated operational power AC-1 (NC): 5.8 kW at 230 V single phase and 17.3 kW at 400 V three phase. Rated insulation voltage 500 V; rated impulse withstand voltage 6 kV. Degree of protection IP20. Dimensions 36 mm wide, 85 mm high, 65 mm deep; net weight 0.235 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB25-13N-01
The ABB ESB25-13N-01 is a four-pole installation contactor for distribution boards, measuring 36 mm wide, 85 mm high, and 65 mm deep, with a net weight of 0.245 kg. It has three main NC contacts and one main NO contact. Rated operational voltage is 220 V DC and 400 V AC on the main circuit; rated control circuit voltage is 24 V. Rated operational current is 25 A at AC-1 and AC-7a for both NC and NO contacts. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Degree of protection is IP20, pollution degree 3, and operating ambient air temperature is -25 to +55 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.