- ESB40-31N-06
The ABB ESB40-31N-06 is a four-pole building contactor with three normally open main contacts and one normally closed main contact. It measures 54 mm wide, 85 mm high, and 65 mm deep, with a net weight of 0.405 kg and a width of 3.0 modular spacings. The main circuit is rated 220 V DC and 400 V AC, with a rated insulation voltage of 500 V and a rated impulse withstand voltage of 6 kV. Rated operational current is 40 A for NO and 30 A for NC at AC-1, and 22 A at AC-3 at 230 V single-phase or 400 V three-phase. The control circuit is rated 230 V. It carries IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- ESB40-40N-01
The ABB ESB40-40N-01 is a four-pole building contactor with four normally open main contacts and no auxiliary contacts. It measures 54 mm wide, 85 mm high, and 65 mm deep, and weighs 0.405 kg. The rated control circuit voltage is 24 V. Main circuit rated operational voltage is 220 V DC and 400 V AC. Rated operational current is 40 A at AC-1 and 40 A at AC-7a; at AC-3 and AC-7b it is 22 A at 230 V single-phase and 22 A at 400 V three-phase. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Degree of protection is IP20, pollution degree 3, and mechanical durability is 1,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, and UL 60947-4-1.
- ESB40-40N-02
The ABB ESB40-40N-02 is a 4-pole building contactor with four normally open main contacts and no auxiliary contacts. It measures 54 mm wide, 85 mm high, and 65 mm deep, and weighs 0.405 kg. The main circuit is rated 220 V DC and 400 V AC, with a rated insulation voltage of 500 V and a rated impulse withstand voltage of 6 kV. Rated operational current is 40 A in AC-1 and AC-7a, and 22 A in AC-3 and AC-7b at 230 V single-phase and 400 V three-phase. The control circuit is rated 42 V at 50 Hz, 60 Hz, 400 Hz, or DC. It provides IP20 protection and 1,000,000 mechanical cycles.
- ESB40-40N-03
The ABB ESB40-40N-03 is a four-pole building contactor with four normally open main contacts and no auxiliary contacts. It measures 54 mm wide, 85 mm high, and 65 mm deep, weighs 0.405 kg, and occupies 3.0 modular spacings. Rated operational voltage is 220 V DC and 400 V AC for the main circuit; rated control circuit voltage is 48 V. Rated operational current is 40 A AC-1 and AC-7a, and 22 A AC-3 and AC-7b at 230 V single-phase and 400 V three-phase. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Degree of protection is IP20, ambient operating temperature range is -25 to +55 °C, and maximum operating altitude is 2000 m. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, and UL 60947-4-1.
- ESB40-40N-04
ABB ESB40-40N-04 building contactor, four-pole (4 NO main contacts, no auxiliary contacts), 3.0 modular spacings wide. Rated operational voltage: main circuit 220 V DC and 400 V AC; rated control circuit voltage 110 V. Rated operational current AC-1 (NO) 40 A; AC-3 (NO) 22 A at 230 V single phase and 22 A at 400 V three phase. Rated operational power AC-1 (NO) 9.2 kW at 230 V single phase and 27.7 kW at 400 V three phase; AC-3 (NO) 3.7 kW and 11 kW respectively. Rated impulse withstand voltage 6 kV, rated insulation voltage 500 V, pollution degree 3, IP20. Dimensions 54 x 85 x 65 mm, 0.405 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB40-40N-05
ABB building contactor ESB40-40N-05, manufacturer ID 1SAE341111M0540. Four-pole installation contactor with four normally open main contacts and no auxiliary contacts. Rated operational current is 40 A in AC-1 and AC-7a, and 22 A in AC-3 at 230 V single-phase and 400 V three-phase. Rated operational voltage is 220 V DC and 400 V AC in the main circuit; rated control circuit voltage is 240 V. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Dimensions are 54 mm wide, 85 mm high, and 65 mm deep, weighing 0.405 kg. Degree of protection is IP20. Mechanical durability is 1,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1.
- ESB40-40N-06
The ABB ESB40-40N-06 is a four-pole building contactor with four normally open main contacts and no auxiliary contacts. It measures 54 mm wide, 85 mm high, and 65 mm deep, weighs 0.405 kg, and occupies 3.0 modular spacings. The rated control circuit voltage is 230 V, with control circuit frequencies of 50 Hz, 60 Hz, 400 Hz, and DC. Main circuit ratings include 220 V DC and 400 V AC. Rated operational current is 40 A in AC-1 and AC-7a, and 22 A in AC-3 and AC-7b at 230 V single-phase and 400 V three-phase. Rated insulation voltage is 500 V, rated impulse withstand voltage is 6 kV, and degree of protection is IP20. Mechanical durability is 1,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB40-40N-07
The ABB ESB40-40N-07 is a 4-pole building contactor with four normally open main contacts and no auxiliary contacts. Rated operational current is 40 A in AC-1 and AC-7a, and 22 A at 230 V single-phase or 400 V three-phase in AC-3 and AC-7b. Rated operational voltage is 220 V DC and 400 V AC in the main circuit. Rated insulation voltage is 500 V, rated impulse withstand voltage 6 kV, and degree of protection is IP20. Dimensions are 54 mm wide, 85 mm high, and 65 mm deep, with a net weight of 0.4 kg. It occupies 3.0 modular spacings. Standards listed include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.