- OVR T2-T3 1N 20-275 P QS
The ABB OVR T2-T3 1N 20-275 P QS is a two-pole plug-in surge protective device for DIN-rail mounting. It is classified as arrester class II and III and is intended to protect systems against transient overvoltage (lightning) in TT and TN-S low-voltage distribution systems. Rated voltage (Ur) is 400 V AC, with a nominal system AC voltage (Uo) of 230 / 400 V and maximum continuous operating voltage (Uc) of 275 V L-PE. Voltage protection level (Up) is 1.4 kV L-N and 0.9 kV N-PE. Nominal discharge current is 5 kA (8/20 µs) and maximum discharge current is 20 kA (8/20 µs); impulse current is 2 kA (10/350 µs). Short-circuit withstand Icc is 100 kA. It provides IP20 protection, a status indicator, and dimensions of 35.6 mm width, 88 mm height, and 58 mm depth, weighing 0.24 kg.
- OVR T2-T3 1N 20-275 P TS QS
The ABB OVR T2-T3 1N 20-275 P TS QS is a plug-in surge protective device for TT and TN-S low-voltage distribution systems, intended to protect systems against transient overvoltage such as lightning. It is rated 400 V AC, with a nominal system AC voltage of 230 / 400 V and maximum continuous operating voltage (L-PE) of 275 V. Voltage protection level is 1.4 kV (L-N), 0.9 kV (N-PE), and 1.4 kV. Nominal discharge current is 5 kA (8/20 µs), maximum discharge current is 20 kA (8/20 µs), and impulse current is 2 kA (10/350 µs). It has two protected poles, one NC and one NO auxiliary contact, a status indicator, IP20 protection, and DIN-rail mounting. Standards: IEC 61643-11 / EN 61643-11.
- OVR T2-T3 20-275 C QS
The ABB OVR T2-T3 20-275 C QS is a DIN-rail mounted surge protective device classified as arrester class II and III, with one protected pole. It is rated 230 V AC (system 230/400 V) with maximum continuous operating voltage 275 V L-PE and temporary overvoltage test value 337 V. Voltage protection level is 0.9 kV L-N and 1.4 kV N-PE. Nominal discharge current is 5 kA (8/20 µs), maximum 20 kA (8/20 µs), and impulse current 2 kA (10/350 µs). Rated service short-circuit breaking capacity and short-circuit withstand are 100 kA. It complies with IEC 61643-11 and EN 61643-11, suits TT, TN-C, and TN-S systems, and has a plug-in replacement cartridge, status indicator, IP20 protection, and 17.6 mm width.
- OVR T2-T3 20-275 P TS QS
The ABB OVR T2-T3 20-275 P TS QS is a plug-in surge protective device for DIN-rail mounting, with one protected pole and one conductor. It is rated for TT, TN-C, and TN-S low-voltage distribution systems, with a rated voltage (Ur) of 400 V AC and a system nominal AC voltage (Uo) of 230 / 400 V. Maximum continuous operating voltage (Uc) is 275 V (L-PE); voltage protection level (Up) is 1 kV (L-N). Nominal discharge current is 5 kA (8/20 µs), maximum discharge current is 20 kA (8/20 µs), and impulse current is 2 kA (10/350 µs). Short-circuit withstand Icc is 100 kA. It provides one NC and one NO auxiliary contact, a status indicator, IP20 protection, and dimensions of 17.8 mm by 95 mm by 58 mm.
- OVR T2-T3 20-440 C QS
The ABB OVR T2-T3 20-440 C QS is a plug-in surge protective device for DIN-rail mounting, intended to protect systems against transient overvoltages including lightning. It is rated 400 V AC, with maximum continuous operating voltage (L-PE) 440 V, voltage protection level 1.4 kV (L-N), 1.4 kV (N-PE), and 1.4 kV. Nominal discharge current (8/20 µs) is 5 kA, maximum discharge current (8/20 µs) is 20 kA, and impulse current (10/350 µs) is 2 kA. Short-circuit withstand and rated service short-circuit breaking capacity are 100 kA. It is declared to IEC 61643-11 and EN 61643-11, for TT, TN-C, TN-S, and IT systems, arrester class II III, one protected pole, IP20, 17.6 mm wide, 57 mm high, 55.6 mm deep, 0.12 kg, with status indicator and replacement cartridge option.
- OVR T2-T3 20-440 P QS
The ABB OVR T2-T3 20-440 P QS is a plug-in surge protective device for DIN-rail mounting, with one protected pole and one conductor. It is rated for TT, TN-C, TN-S, and IT low-voltage distribution systems and complies with IEC 61643-11 and EN 61643-11. Maximum continuous operating voltage is 440 V (L-PE), rated voltage is 690 V AC, and the nominal AC system voltage is 400 / 690 V. Voltage protection level is 1.4 kV (L-N). Nominal discharge current is 5 kA (8/20 µs), maximum discharge current is 20 kA (8/20 µs), and impulse current is 2 kA (10/350 µs). Short-circuit withstand is 100 kA. The device measures 17.8 mm wide, 88 mm high, and 58 mm deep, weighs 0.12 kg, and has IP20 protection and a status indicator.
- OVR T2-T3 20-440 P TS QS
ABB OVR T2-T3 20-440 P TS QS surge protective device, arrester class II III, plug-in version for DIN-rail mounting. One protected pole, one conductor, one modular spacing, 17.8 mm wide, 95 mm high, 58 mm deep, 0.12 kg. Rated voltage 690 V AC; nominal system AC voltage 400 / 690 V; maximum continuous operating voltage (L-PE) 440 V; voltage protection level 1.4 kV (L-N) and 1.8 kV; temporary overvoltage test value 581 V. Nominal discharge current (8/20 µs) 5 kA, maximum (8/20 µs) 20 kA; impulse current (10/350 µs) 2 kA. Rated service short-circuit breaking capacity and short-circuit withstand 100 kA. Standards IEC 61643-11 / EN 61643-11. Suitable for TT, TN-C, TN-S and IT systems. Status indicator provided; one NC and one NO auxiliary contact, auxiliary circuit 12 Vdc - 10 mA minimum to 250 Vac - 1 A. IP20.
- OVR T2-T3 3L 20-275 P TS QS
The ABB OVR T2-T3 3L 20-275 P TS QS is a plug-in surge protective device for TN-C low-voltage distribution systems, intended to protect systems against transient overvoltage (lightning). It is a three-pole device with three protected poles and three conductors, DIN-rail mounted, with a width of 3 modular spacings (53.4 mm). Rated voltage Ur is 400 V AC; nominal system voltage Uo is 230 / 400 V; maximum continuous operating voltage Uc is 275 V (L-PE). Voltage protection level Up is 0.9 kV (L-N). Nominal discharge current is 5 kA (8/20 µs) and maximum discharge current is 20 kA (8/20 µs); impulse current is 2 kA (10/350 µs). Short-circuit withstand Icc is 100 kA. It provides one NO and one NC auxiliary contact, a status indicator, IP20 protection, and operates without derating up to 5000 m altitude. Standards: IEC 61643-11 / EN 61643-11.