Industrial Automation Parts. Prompt replies from real people.

ABB DS201 B16 A30 RCBO

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB DS201 B16 A30?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB DS201 B16 A30 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
DS201 B16 A30
Material Number
2CSR255180R1165
Manufacturer
ABB
Product ID
81144

Get a Free Quote

Request pricing and availability for DS201 B16 A30.

More parts to source? Send your whole list in one enquiry

Key specifications

Rated Operational Voltage
acc. to IEC 60898-1 240 V
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 500 V
Rated Current (In)
16 A
Rated Frequency (f)
50 … 60 Hz
Degree of Protection
IP20 IP40
Product Net Weight
200 g
See all specifications

Product Highlights

  1. Standards and approvals: Complies with IEC/EN 61009-1 and IEC/EN 61009-2-1 and carries a CE Declaration of Conformity
  2. Protection ratings: 16 A rated current, 30 mA Type A residual current, B tripping characteristic, 6 kA rated short-circuit capacity, 10 kA rated ultimate short-circuit breaking capacity and 7.5 kA rated service short-circuit breaking capacity
  3. Electrical characteristics: 240 V rated operational voltage, 500 V rated insulation voltage, 4 kV rated impulse withstand voltage, 50 to 60 Hz rated frequency and 4.5 W total power loss
  4. Terminations and mounting: Failsafe bi-directional cylinder-lift screw terminals with 2.8 N·m tightening torque, 12 mm wire stripping length, 0.75 to 25 mm² solid-core and 0.75 to 16 mm² stranded connecting capacity, DIN-rail mounting in any position
  5. Operating conditions and endurance: -25 to 55 °C ambient air temperature, IP20/IP40 degree of protection, pollution degree 2, 10000 electrical cycles and 20000 mechanical cycles
  6. Indication and testing: Red ON / green OFF contact position indication, blue fault flag on the toggle and a test pushbutton for functional verification
  7. Accessories: Compatible with auxiliary contacts, signal contacts, shunt trips, overvoltage releases and motor operating devices
DS201 B16 A30

Product Information

Technical Specifications

Specifications for DS201 B16 A30

ParameterValue
StandardsIEC/EN 61009-1, IEC/EN 61009-2-1
Tripping CharacteristicB
Type of Residual CurrentType A
Rated Operational Voltageacc. to IEC 60898-1 240 V
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 500 V
Test Voltage (Ut)170 ... 264 V
Rated Impulse Withstand Voltage (Uimp)4 kV
Dielectric Test Voltage2 kV
Input Voltage TypeAC
Rated Current (In)16 A
Rated Residual Current30 mA
Rated Short-Circuit Capacity6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)10 kA
Rated Residual Breaking Capacity (IΔm)EN 61009-1 6000 A IEC 61009-1 6000 A
Rated Conditional Short-Circuit Current (Inc)10 kA
Rated Service Short-Circuit Breaking Capacity (Ics)7.5 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)6 kA
Rated Frequency (f)50 … 60 Hz
Power LossAverage per Pole 2.3 W Phase Pole 3.4 W Neutral Pole 1.2 W Total 4.5 W
Power Supply ConnectionArbitrary
Contact Position IndicationRed ON / Green OFF
Energy Limiting Class3
Electrical Endurance10000 cycle
Mechanical Endurance20000 cycle
Number of Protected Poles1
Number of Poles2
Number of Modular Spacings per DIN Rail2
Fault IndicationBlue flag on toggle
Operating CharacteristicInstantaneous
Overvoltage CategoryIII
Position of Neutral TerminalsRight
Tightening Torque2.8 N·m
Accessory TypeAuxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device
Actuator TypeToggle - Insulation group II, Black RAL 9005, sealable in ON-OFF positions
ParameterValue
Earthing Switch TypeUndelayed
Housing TypeInsulation group I - II, RAL 7035
Mounting TypeDIN-Rail
Screw Terminal TypeFailsafe Bi-directional Cylinder-lift Terminal
Mounting PositionAny
Accessories AvailableYes
Number of Batteries0
Connecting CapacityBusbar 10 ... 10 mm² Stranded 0.75 ... 25 mm² Flexible with Ferrule 0.75 ... 16 mm² Flexible 0.75 ... 16 mm²
Rated Cross-Section1 - Solid-Core 0.75 … 25 mm² 4 - Multi-Wired 0.75 … 16 mm²
Wire Stripping Length12 mm
Terminal TypeScrew Terminals
Ambient Air TemperatureOperation -25 … 55 °C
Reference Ambient Air Temperature30 °C
Degree of ProtectionIP20 IP40
Pollution Degree2
Environmental Conditions28 cycles with 55 °C90-96 % and 25 °C95-100 %
Resistance to Vibrations20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-2725g 2 shocks 13 ms
Environmental Information2CSC422002K2701
Width in Number of Modular Spacings2
Product Net Width35 mm
Product Net Height85 mm
Product Net Depth / Length69 mm
Product Net Weight200 g
Built-In Depth (t2)69 mm
Dimension Diagram9AKK107492A6185
ETIM 8EC000905 - Earth leakage circuit breaker
ETIM 9EC000905 - Earth leakage circuit breaker
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2BBusiness To Consumer
CN885363010
UNSPSC39121601
eClassV11.0 : 27142207
IDEA Granular Category Code (IGCC)4875 >> Residual current circuit breaker (RCCB)
Object Classification CodeF
Manufacturer ID2CSR255180R1165

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp